36
"Problem”
A. No transmission
(motor will not run)
B. No ignition (spark)
C. No sound signal
D. One continuous sound signal of 5
sec.
(Possible 7 short beeps prior to the 5
sec. sound signal)
E. No pilot burner flame
1. The (new) communication code
between receiver and remote control
must still be confirmed.
2. Empty batteries.
3. Receiver is damaged.
4. Remote control is damaged.
5. Motor cable at valve/receiver is
broken.
6. Bent pins of the 8-wire connector.
7. If the receiver is surrounded by
metal, this could decrease the trans-
mission range.
1. Button A in position MAN.
2. Ignition cable runs over and/
or alongside metal parts.
3. Ignition pen corroded.
4. 60-second delay before the full
restart is not yet finished.
1. Receiver is damaged.
2. 60-second delay before the full
restart is not yet finished.
1. Loose wiring between receiver and
gas control.
2. Receiver is damaged.
3. Bent pins of the 8-wire con- nector.
4. Damaged magnetic valve.
1. Air in the pilot burner pipe.
2. Wires of thermocouple have been
cross-connected.
3. No spark at the pilot burner.
4. Injector is blocked up.
1. Hold down the reset button of the
receiver, until you hear a long beep
. Let go of the reset button after the
second, longer sound signal and press
button (small flame) on the remote
control within 20 sec., until you hear a
sound signal confirming that the new
code has been set.
2. Replace batteries.
!Caution Avoid short circuit between
the batteries and metal parts of the
appliance.
3. Replace the receiver and confirm
the code (remedy 1).
4. Replace the remote control and
confirm the code (remedy 1).
5. Replace the motor cable.
6. Make sure that the pins of the
8-wire connector are straight.
7. Change the position of the an-
tenna.
1. Switch button A on the gas control
to
ON (figure 1)
2 Do not place the ignition cable over
and/or along metal parts. This will
weaken the spark;
If necessary, replace the ignition cable.
3. Replace the ignition pen.
4. Wait until the delay time has
passed.
1. Replace the receiver and confirm
the code (remedy 1 at A)
2. Wait until the delay time has
passed.
1. Connect the wiring properly.
2. Replace the receiver and confirm
the code (remedy 1 at A)
3. Make sure that the pins of the
8-wire connector are straight.
4. Replace the gas control.
1. Flush the pipe or start the ignition
process several times.
2. Check the polarity of the thermo-
couple wiring.
Connect the thermocouple wiring pro-
perly, if necessary.
3.1 Check if the ignition cable is lying
free from metal parts;
If necessary, move it away from the
metal parts.
3.2 If necessary, replace the ignition
cable.
3.3 If necessary, replace the ignition
pen.
4.1 Clean the injector.
4.2 If necessary, replace the injector.
"Possible cause”
"Remedy”
TROUBLE SHOOTING
Summary of Contents for Modore 100 H
Page 15: ...15 INSTALLER INFORMATION 15 INFORMATIE VOOR DE INSTALLATEUR...
Page 16: ...16 INSTALLER INFORMATION 16 INFORMATIE VOOR DE INSTALLATEUR...
Page 17: ...17 INSTALLER INFORMATION 17 INFORMATIE VOOR DE INSTALLATEUR...
Page 18: ...18 INSTALLER INFORMATION 18 INFORMATIE VOOR DE INSTALLATEUR...
Page 42: ...42...
Page 43: ...43...
Page 44: ...Element4 B V Paxtonstraat 23 8013 RP Zwolle The Netherlands September 2014...