18
CLEARANCES
Element4 Gas Fireplaces Rev# 07082020
European
Home
.com
TYPICAL CLEARANCE DIAGRAMS
Minimum Required Air Opening Sizes
Room Air Inlet
Warm Air Outlet
Model
Square
Inches
Square
Centimeters
Square
Inches
Square
Centimeters
Lucius 140 GSB
145
936
145
936
Tenore 140 GSB
145
936
145
936
Minimum Distances
A
Room ceiling to
appliance bottom
72”
1830
mm
B
Chase ceiling to top
of Warm Air Outlet
1”
25
mm
B
A
Warm Air
Outlet
The total area of the air openings must be maintained. The location of the openings must allow for the free movement of air and
must not allow excessive warm air to build up within the chase.
The top of the Warm Air Outlet must be
no more
than 1” (25 mm) down from the
chase
ceiling.
The minimum distance from the bottom of the appliance to the room ceiling is 72” (1830
mm)
.
Figure 18
Figure 19
Figure 20