6 FIRE SAFE INSTALLATION
To install a gas fireplace as safely as possible, several installation
preparations need to be made. This overview can be used to
assure the fire safety of a conversion of a fireplace.
6.1 Fire safety device set-up
Install the device such that there are no flammable materials
around the device or chimney. The device must never be placed
against a back wall of flammable materials.
Flammable materials, such as wood, can combust at a
temperature of 85°C. At high temperatures this can happen
within several minutes (over 200°C) or at lower temperatures
(more than 85°C) this may occur over a period of weeks.
A gas fireplace can achieve temperatures of over 200°C.
Therefore one should use only non-flammable materials around
the fireplace and in the cove.
It is important to follow the installation regulations below
carefully. When the regulations are insufficiently- or not provided
with the aspects of fire safety, the instructions according to NPR
3378-20:2010 are leading.
6.1.1 Protection of wall and ceiling
There are two kinds of walls/ceilings that can be distinguished,
respectively;
1. Walls/ceilings that are made of – or contain flammable
building materials, and all walls on which flammable objects
(e.g. built-in furniture or wooden panels) are mounted on
the side of the wall that is turned away from the fireplace.
2. Walls/ceilings made of mineral building materials (gas
concrete, bricks, lime sandstone etcetera.) of more than
10cm thickness.
6.2 Assembly regulations
6.2.1 Assembly regulations for non-flammable materials
(
Figure 6.1
and
6.2
)
•
Cover the walls/ceilings with a non-flammable, fire resistant
plate, according to EN 13501-1:A2
•
Place a non-flammable, fire resistant plate in front of the
first one at a distance of 2cm.
•
Make sure that the two plates are not attached to each other
by screws or nails. Due to their conductivity these metals
can cause problems.
#
Description
A
Insulation (near ceiling)
B
Distance to false ceiling (
≥100mm)
C
False ceiling
D
Layer of insulation
E
Distance to layer of insulation (
≥20mm)
F
Casing of non flammale material
G
Distance to convection grate (
≥300mm)
H
Convection grate (2x150cm
2
)
I
Outside of the firplace (~200°C)
J
Radiation distance to flammable objects (
≥500mm)
K
Distance fire to non flammable floor (
≥100mm)
L
Air cavity (
≥50mm)
M
Flammable wall
N
Non-flammable wall
O
Flammable floor
P
Non-flammable floorboard
Q
Non-flammable cover
Summary of Contents for CLUB 240
Page 1: ...INSTALLATION MANUAL PLEASE LEAVE THESE INSTRUCTIONS BEHIND WITH THE DEVICE C L U B 2 4 0 ...
Page 2: ......
Page 16: ...INSTALLATION MANUAL 16 ...
Page 17: ...APPENDICES 17 APPENDICES ...
Page 31: ...APPENDICES 31 I 2 Technical drawing of Club 240 F ...
Page 32: ...APPENDICES 32 Figure I 3 Technical drawing of Club 240 C ...
Page 33: ...APPENDICES 33 I 4 Technical drawing of the Club 240 RD ...
Page 35: ......