Resistance Welder MULTISPOT MI-90 T
Maintenance
38
8.2.2
Maintaining the pneumatic unit
Fig. 36: Pneumatic unit
1.
Visually check the compressed-air filter (Fig. 36).
Replace, when you see any accumulation of dirt.
2.
Visually check the water separator under the compressed-air
filter for residues of water.
If you find any accumulations of water, pull of the cap in the
direction indicated by the arrow and empty water from the
separator.