4
The sound level of the unit is smaller as 70 dB (A) measured
at standard load conforming EN 60 974 at the max. work-
point.
Depending on the operation, users of commercially operated
welding systems are obliged to have safety inspections of the
equipment carried out regularly in accordance with
VDE 0544-207. ELEKTRON recommends inspection periods
of 12 months.
A safety inspection must also be carried out after alterations
or repair of the system.
! Caution !
: Improperly carried out UVV inspections can de-
stroy the system.
For more information on UVV inspections of welding systems,
please contact your authorized service center.
This product is manufactured conform to the current EMV
standard. Please notice following items:
The unit is for welding under commercial or industrial con-
ditions. The use in other surroundings (for example in res-
idential areas) may disturb other electric devices.
During welding electromagnetic problems can be caused
at:
– Mainscables, controlcables, connections for telecom-
munication
– TV / Radio
– Computer and other similar devices
– Protection devises as for example alarm systems
– Pacemakers and hearing aids
– Devices for measure and calibrate
– Devices with less protection against disturbances
If other devices are disturbed it may be necessary to pro-
tect additionally.
The affected area can be bigger than your premises /
property depends of the building etc.
Please use the unit conform to the instructions of the manu-
facturer. The user is responsible for installation and use of the
machine. Furthermore the user is responsible to eliminate the
disturbances caused by electromagnetic fields.
5 Emission of sound
6 UVV inspection (UVV = regulations
for prevention of accidents)
7 Electromagnetic compatibility (EMV)
8 Technical data
Type
MULTIMIG 400puls
Welding
Welding range (I
2min
-I
2max
/
U
2min
-U
2max
)
A/V
25 – 320/
15.2 – 30
No load voltage
V
81
Voltage adjustment
continuously variable
Slope characteristic
constant / falling
Duty cycle 100 % 40 °C
A
250
Duty cycle 60 % 40 °C
A
270
Duty cycle at max. current 40 °C
%
35
weldable wire steel
Ø mm
0.6 – 1.2
weldable wire alu
Ø mm
1.0 – 1.2
welding electrodes
Ø mm
1.0 – 6.0
Wire-feed speed
m/min
0.1 – 25
Mains
Mains voltage 3~ (50/60 Hz)
V
400
Mains voltage tolerance range
%
+/- 15
Input power S1 (100 %/40 °C)
kVA
10.7
Input power S1 (60 %/40 °C)
kVA
12.6
Input power S1 (max. current)
kVA
15.1
Current input I1 (100 %/40 °C)
A
15.5
Current input I1 (60 %/40 °C)
A
18.2
Current input I1 (max. current)
A
21.8
Power factor (at I
2max
)
cos
ϕ
0.99
Mains fuse
A/tr
16
Mains plug
CEE16
Unit
Protection class (EN 60 529)
IP23
Insulation class
F
Cooling method
F
Noise emission
dB (A)
<70
Summary of Contents for MULTIMIG 400puls
Page 2: ...2 5 5 6 10 8 9 6 7 12 15 14 11 10 ...
Page 19: ...19 Appendix mounting torch holder ...
Page 20: ...326601 06 05 ...