MULTIMIG 200
Electromagnetic compatibility (EMC)
7
7
Ambient conditions
Temperature range of ambient
air:
In operation:
-10 °C … +40 °C (+14 °F … +104 °F)
Transport and storage:
-25 °C … +55 °C (-13 °F … +131 °F)
Relative humidity:
up to 50 % at 40 °C (104 °F)
up to 90 % at 20 °C (68 °F)
-25 °C … +55 °C (-13 °F … +131 °F)
Operation, storage and transport
may only be carries out within the
ranges indicated! Use outside of
this range is considered not used
with its intended purpose. The
manufacturer is not liable for dam-
ages cause by misuse.
Ambient air must be free of dust, acids, cor-
rosive gases or other damaging substances!
8
UVV inspection
Operators of commercially-operated welding
systems are obliged to have safety inspections
of the equipment carried out regularly in
accordance with VDE 0544-4. ELEKTRON
recommends inspection intervals of 12 months.
A safety inspection must also be carried out
after alterations or repair of the system.
Improper UVV inspections can
destroy the system.
9
Electromagnetic compatibility
(EMC)
This product is manufactured in conformance
with the current EMC standard. Please note
the following:
The machine is intended for welding in both
commercial and industrial applications
(CISPR 11
class A).
Use
in
other
surroundings (for example in residential
areas) may disturb other electronic devices.
Electromagnetic problems during start-up
can arise in:
•
Mains cables, control cables, signal and
telecommunication lines near the welding or
cutting area
•
TVs / radios
•
Computers and other control equipment
•
Protection equipment such as alarm
systems
•
Pacemakers and hearing aids
•
Equipment for measurement and calibration
•
Equipment with too little protection against
disturbances
If other equipment is disturbed it may be
necessary to provide additional shielding.
The affected area can be bigger than your
premises/property. This depends on the
building, etc.
Please use the machine in compliance with the
manufacturer's instructions. The machine
operator is responsible for installation and use
of the machine. Furthermore, the owner is
responsible for eliminating the disturbances
caused by electromagnetic fields.