![Elektron 328 008 Operating Manual Download Page 30](http://html1.mh-extra.com/html/elektron/328-008/328-008_operating-manual_2386798030.webp)
Resistance Welder MULTISPOT MI-100-3
Operation
30
Adjusting the distance between
electrodes
Fig.33: Adjusting the distance between
electrodes
Make sure the distance between the electrodes is 6 to 8 mm.
Carry out the first welds, and then check the distance again.
Re-adjust, if necessary.
Use an Allen key SW5 as gauge in between the tips:
Electrode tip Allen key Electrode tip
Aligning electrodes
Fig.34: “Electrode must be in true
alignment”
Be sure to look from different angles. Electrodes must align no
matter how you look.
6.1.3
Checks before switching on
WARNING ! Unskilled employees may hurt themselves and others. Inexpert operation
constitutes a hazard of injuries.
Inexpert and/or negligent handling of this equipment and/or ignorance of hazards and dangers
may entail the most severe injuries. Therefore:
−
Make sure this equipment is put to use by skilled welding operators with sufficient training
and experience in spot welding, exclusively.
−
Before operation, consult the manual and make sure any and all preconditions are fulfilled,
any and all checks and preliminary works etc. have been carried out.
−
Work place must be clean and tidy – no clutter. Make sure you have enough room to move.
Be sure to be wearing adequate PPE. (
See “2.2.3”.)
Check any and all connections. (
See “5”.)
Check input pressure. (
See “5.5”.)
Check cooling water level. (
See “5.2”.)
Check your tools / welding pliers). Re-tool now, if necessary.
(
See “6.1.2” and/or separate operating instructions for welding pliers.)