![Elektron 328 008 Operating Manual Download Page 22](http://html1.mh-extra.com/html/elektron/328-008/328-008_operating-manual_2386798022.webp)
Resistance Welder MULTISPOT MI-100-3
Installation
22
5
Installation
5.1 Before installation
5.1.1
Preliminary works
Check operating conditions according to specifications. (
See “9”.)
If necessary, allow equipment time to adapt to ambient temperature SLOWLY.
Make sure that operating company’s supply systems comply with specifications. (
See “9”.)
Before you start any works, make sure the work area is tidy, clean and free of clutter and offers
enough room to move.
Make sure your tools are complete and in good working order.
Do wear safety shoes.
5.2 Filling up cooling water tank
Fig. 16: Filling up the cooling water tank
1.
Remove the cover on the rear side, the coolant outlet and coolants return.
2.
Remove cooling water tank raise and turn off cooling water tank cap.
3.
Fill about 30 litres / 7.9 gallons of cold, clean drinking water into the tank.
4.
Add chlorine-free disinfectant to prevent growth of algae and bacteria.
5.
Replace cap properly. Check for tightness.
6.
Move the cooling water tank back. Put in the coolant outlet and coolant return into the tank; put on
the rear cover.
7.
Before you switch on the welder, check the coolant level before each use and, if necessary, top up
coolant.
NOTE!
For draining the tank,
see”8.2.4