3.3.3.5 Menu “About HW, SW...”
This menu page displays an overview of device relevant data such as serial number, article number etc.
3.3.3.6 Menu “Function Generator”
See
„3.8 The function generator“ on page 61.
3.3.3.7 Menu “Communication”
Here settings for digital communication via the optional interface modules (abbr. IF) of the IF-AB series are made.
The touch area “Configure interface” opens one or more settings pages, depending on the module in use.
For all Ethernet interfaces with two ports: „P1“ is related to port 1 and „P2“ to port 2, like printed
on the module face. Two-port interfaces will use one IP only.
IF Level 1
Level 2
Level 3 Description
Ethernet / ModBus-TCP
, 1 & 2 Port
IP Settings
DHCP
The IF allows a DHCP server to allocate an IP address, a subnet
mask and a gateway. If no DHCP server is in the network then net-
work parameters will be set as defined in item “Manual”
Manual
IP
This option is activated by default. An IP address can be maually
allocated.
Gateway
Here a gateway address can be allocated if required..
Subnet
Here a subnet mask can be defined if the default subnet mask is
not suitable.
DNS 1
Here the addresses of the first and second Domain Name Servers
(DNS) can be defined, if needed. A DNS is only necessary if the
device has Internet access and should call Internet URLs, e.g. an
internal eMail system, in order to send an eMail.
DNS 2
Port
Range: 0...65535. Default ports:
5025 = Modbus RTU (all Ethernet interfaces)
502 = Modbus TCP (Modbus-TCP interface only)
IP Com
Settings P1
IP Com
Settings P2
AUTO
Settings for the Ethernet port such as transmission speed are set
automatically.
Manual
Half dup
Manual selection for transmission speed (10MBit/100MBit) and
duplex mode (full/half). It is recommended to use the “AUTO” option
and only revert to “Manual” if these parameters fail.
Full dup
10MBit
100MBit
Host name
Free choice of host name (default: Client)
Domain name
Free choice of Domain (default: Workgroup)
SMTP
Settings
Server IP
Mail server address, used to send eMails via this mail server, in
order to e.g. report an alarm.
Username
Login to Mailserver, Username
Password
Login to Mailserver, Password
IF Level 1
Description
Profibus DP
Node Address
Selection of the Profibus or node address of the device within range 1...125 via
direct input
Function Tag
String input box for a user-definable text which describes the Profibus slave function
tag. Max. length: 32 characters
Location Tag
String input box for a user-definable text which describes the Profibus slave location
tag. Max. length: 22 characters
Installation Date
String input box for a user-definable text which describes the Profibus slave instal
-
lation date tag. Max. length: 40 characters
Description
String input box for a user-definable text which describes the Profibus slave.
Max. length: 54 characters
IF Level 1
Description
RS232
-
There are no configurable parameters for this module. It always uses these serial
settings: Baud rate = 115200 Baud, 8 data bits, 1 stop bit, parity = none