21
- MY575 SPOT
Channel 16 – Lamp on/off, reset, internal programs:
0-19 colour change normal by direction depend on distance
20-39 colour change to any position by direction depend on distance
40-59 Lamp on
60-79 Lamp switch off
80-99 Motor reset
100-119 Internal program 1
120-139 Internal program 2
140-159 Internal program 3
160-179 Internal program 4
180-199 Internal program 5
200-219 Internal program 6
220-239 Internal program 7
240-255 Internal program 8
Channel 17 – Pan fine 16bit
Channel 18 – Tilt fine 16bit
ERROR MESSAGE
When you turn on
MY575
, it will make a reset first. The display may show “XXer” while there are problems with
one or more channels. “XX” stands for channel 1,2,3,4,5,6,8,12,14,15 who has the testing sensor for
positioning .
For example, when the display shows “02Er”, it means there is some error in channel 2. If there are some
errors on channel 1, channel 2, channel 5 at the same time, you may see the error message “01Er”,
“02Er”,”05Er” flash repeated for 5 times, and then
MY575
will generate a reset signal, all the stepper reset. If
the error message remains after performing reset more than 3 times, it will detect whether the fixture has more
than 3 errors. If the fixture has 3 errors or more, then all the channels will not work properly. However if the
fixture has less than 3 errors, only those channels which have errors will not work properly, other channels will
work as normal.
01Er:
(Color-wheel 1 error) This message will appear after the reset of
MY575
if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the
main circuit card). The color wheel will not be located in the default position after the reset.
02Er:
(Rotating gobo-wheel 1 error) This message will appear after the reset of
MY575
if the magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on
the main circuit card). The rotating gobo-wheel will not be located in the default position after the reset.