a)
Installing or replacing the lamp
Only install the lamp when
MY575
is unplugged from 120 volts.
The lamps must be replaced when it has reached the end of its lamp life or if it is damaged or deformed.
Before replacing the lamp let the lamp cool down. During operation, the lamp can
reach very high temperature.
During the installation of the lamp do
not
touch the glass bulbs with bare hands. Always use a cloth to handle
the lamps during insertion and removal.
Do not install lamps with a higher wattage. They generate temperatures higher than
MY575
operating
temperature
.
For the installation, you need one MSR 575/2 lamp :
Procedure:
1) Unscrew the 3 screws (A, B, C) on the bottom of the housing, holding the plate under which the lamp is
located. Carefully remove the metal plate.
2) Carefully insert the lamp into the socket. Please remember the lamp is polarized. There is only one way to
insert the lamp. Gently slide the lamp and its lamp holder back into place.
3) On the access plate there are 3 screws marked 1, 2 and 3. They are used to adjust the lamp. You can
adjust the 3 screws to fine-tune the position of the lamp and get the maximum light output.
2
3
1
2
1
3
Please remember the lamp is not hot-restrike. You must wait approximately 10
minutes before you can restrike the lamp.
Do
not ever
operate
MY575
with the cover open. The lamp is a discharge lamp. All discharge lamps,
irregardless of the manufacturer or type, are very volatile and can
explode
. Great caution must be exercised
when working with these lamps otherwise
serious injury can happen.