background image

10. Address (For DMX & ID)

DMX Address

Sets up the address for the dmx. 
Using the Menu button in the root menu go to DMX
Press Enter to get into DMX and the display will read the current dmx channel.
The display will read for example 

DMX:

001 

This means the fixture's current address is 

1

To change it, use the ↑ or ↓ buttons to get to the correct address. Press Enter to save the address.
Now immediately Enter is pressed, the ID address for the fixture is shown. See below for ID address 
information; otherwise press Enter to exit out and back to the Root Menu again.

ID Address

An 

elektraLite UV

 can be addressed (controlled) through the dmx or instead it can have its own unique 

ID address.
There are a total of 255 different ID addresses from 001 to 255.
To set up the address for a fixture, use the Menu button in the root menu go to 

ID

Press Enter and then using the ↑ or ↓ buttons,to  select the ID address.
Press Enter to save the address. 
For the ID address to work you must chose a 

Personality

 that uses the ID. For example STAG

This allows you to access the ID address system on channel 4.
Set the DMX address to 001 for the fixture. So if ID address 123 is chosen then go to channel 4 on the 
lighting board and set the level at 123. You will then be controlling only fixture(s) with ID address 123.
ID address 001 is the default and in ID address 001 all fixtures will be under control.

11. Personalities.

There are three different choices on how the fixture will operate.
What these "Personalities" do in terms of their channel assignments is detailed in the tables on page 7.
To change a Personality use the Menu button to get to 

PERS

Press Enter then using the ↑ or ↓ buttons go to the personality required.
Press Enter to save the Personality.

12. Settings. 

(Set has several Sub Menus which allow the following functions to be used).

1). 

Dimmer

The Dimmer function allows different Dimmer curves to be chosen. There are 5 choices. 
Choice   1:-   this   is   Dim   off.   The   Dimmer   curve   is   0   which   means   any   change   in   dimmer   level   is 
instantaneous.
Choice 2:- Dim 1. The dimmer curve has the shortest fade in and fade out time.
Choice 3:- Dim 2. The dimmer curve has the 2

nd

 shortest fade in and fade out time.

Choice 4:- Dim 3. The dimmer curve has the 3

rd

 shortest fade in and fade out time

Choice 5:- Dim 4. The dimmer curve has the longest fade in and the fade out time.
To access the DIM function go through the Root Menu until 

DIMMER 

is found. Press Enter and then use 

the ↑ or ↓ buttons to get to the DIM choice required.

Summary of Contents for eyeBall UV

Page 1: ...elektraLite LED eyeBall UV USER MANUAL elektraLite a division of Group One 70 Sea Lane Farmingdale NY11735 U S A T 1 631 396 0184 F 1 631 396 0190 WWW MYELEKTRALITE COM...

Page 2: ...when dealing with high voltages Please read this manual If you do not read this manual and damages occur to the elektraLite UV then it could void the warranty During shipping the elektraLite UV may ha...

Page 3: ...between the elektraLite UV and the illuminated surface must be more than 3 feet Always mount the elektraLite UV with an appropriate safety cable Operate the elektraLite UV only when you are familiar w...

Page 4: ...cable fitted with a 5 pin XLR input and output connector Please refer to the diagram below 1 2 3 4 5 DMX 512 connection with DMX terminator For installations where the DMX cable has to run a long dist...

Page 5: ...EFFECT 1 inbuilt program 1 EFFECT 2 inbuilt program 2 EFFECT 3 inbuilt program 3 RUN DMX 512 SLAVE ADDRESS ASSIGN DMX CHANNEL 001 512 ASSIGN ID ADDRESS 001 255 PERS PERSONALITY STAG E 1 STAG E 2 CHAN...

Page 6: ...and the static look is complete Pressing the Enter key just continues around if you need to make fine adjustments to the static look Do not press MENU as this will get you out to the Root directory an...

Page 7: ...ess 123 is chosen then go to channel 4 on the lighting board and set the level at 123 You will then be controlling only fixture s with ID address 123 ID address 001 is the default and in ID address 00...

Page 8: ...hen the temperature falls below its pre set value High The fans are constantly on at a high rotational speed Normal The fans are constantly on at their normal rotational speed Low The fans are constan...

Page 9: ...sh 50 99 Asynchronous slow flash 100 149 Random slow flash 150 199 Asynchronous fast flash 200 255 Synchronous fast flash 3 0 10 NO FUNCTION 11 20 FAN OFF 21 25 FAN LOW 26 30 FAN HIGH 31 40 FAN AUTO 4...

Page 10: ...will be a lot more costly than having someone vacuum the fixtures on a regular basis How often should the fans be cleaned It depends on where the fixtures are in a very dusty atmosphere once a week S...

Page 11: ...8 Other Products For other great products that are manufactured under the elektraLite product line please go to the website at www myelektraLite com A preview of the products include elektraLite ML602...

Page 12: ...elektraLite LightStream elektraLite DazerIP65 in white...