eledo Luno5 Manual Download Page 6

 

 

Luno5 light switch manual  

 

 www.eledo.pl   

 

           6 

sp

ots on sensors visible in fig

. 8). H

oles makes transmission of optical signals from sensors possible that enables proper people 

counting

. Y

ou can use included plastic overlays 

(6 pieces) to aesthetically edge around the holes. An example of the assembly of 

sensors on the door frame can be found in figure 9. It is also possible to place the sensors flush with the surface of the door frame 
by drilling 26-mm holes in the door frame and placing the whole sensors there. 

In order to maintain aesthetics, it is recommended to put sensor wires inside the door frame. As the need arises it is possible to 

pull wires through narrow holes, you can cut sensor wires and reconnect them e.g. by a terminal block. Instead of placing sensors 
on  or  inside  the  door  frame  it  is  also  possible  to  place  them  in  front  of  an  entrance  on  the  side  walls  provided  that  the  distance 
between two sensors of a 

particular pair won’t be bigger than 2 m. This way of assembly is convenient because it enables turning 

lights on when the room is closed. In the case when the distance between opposite sensors is bigger than 1 m you can remove the 
white sticker from the sensors to increase device sensitivity. 

 

 

Fig. 8. Placement of direction sensors and wiring 

– enlarged sensors.  

 

                     

      

Fig. 9. An example of installation of sensors outside and inside the door frame (one side visible). 

Summary of Contents for Luno5

Page 1: ...nting out that light switches based on motion sensors leave lights on for an extended time after the person leaves the room The Luno5 device in such case turns light s off almost immediately with a one second delay Luno5 can also switch light s on off with the press of a button regardless of the number of people in the occupied space This function can be useful in situations that require manual op...

Page 2: ...SU Power consumption min 0 3W standby max 0 8W counting Work temperature between 20 C and 40 C Important safety information The device contains no elements that can be serviced by the user In the case of failure it needs to be fixed only by authorized service center The device is intended to be installed inside living compartments in nonindustrial and non damp areas The device cannot be exposed to...

Page 3: ... in the room on During the countdown hand symbol flashes to remind the user that light will be turned off This function is useful when the user s are going to sleep When the light s go off the switch blockage goes on to prevent the switch from turning on when someone incidentally comes into the room To turn off blockage push the button again The blockage also will be turned off automatically after...

Page 4: ...ed for lighting c Luno5 can be powered by an additional 5V power supply that is available at www eledo pl website one power supply can be used in 10 Luno5 devices In such a situation a neutral conductor is no longer in use The device can be powered by a 5V phone charger d you can connect a 5V power supply from other Luno5 switches Two Luno5 devices should be connected by a conductor of at least 0 ...

Page 5: ...itch Wires that lead to sensors are connected to the controller with a fitting fig 14 and to ease assembly you can disconnect them by gently pulling tape attached to wires collaterally to the plane of the PCB Direction sensors should be mounted on door frame sides as fig 8 shows You can use double sided bonding tape to attach them to the door frame It can be found on the rear side of the sensors S...

Page 6: ...e door frame As the need arises it is possible to pull wires through narrow holes you can cut sensor wires and reconnect them e g by a terminal block Instead of placing sensors on or inside the door frame it is also possible to place them in front of an entrance on the side walls provided that the distance between two sensors of a particular pair won t be bigger than 2 m This way of assembly is co...

Page 7: ...it means that the sensors are properly assembled If it displays 3 4 or 5 it means that the sensors are inaccurately placed against each other The less accurate way of checking the sensors proper assembly is the inspection of a stable glow of four red indicator lights located in the controller s upper right corner after the removal of the devices front panel If any indicator is down or fading then ...

Page 8: ...the device won t be able to properly check light intensity inside the room In a bathroom with no windows a solution is quite simple because each entrance should turn the light on there s no need to check the light intensity level In such a case you need to turn the sensor sensitivity regulator fig 5 maximally to the left counterclockwise or permanently cover the light sensor If a bathroom has a wi...

Page 9: ...d it means that the function is on The function needs to be turned off when the device works conversely ie lights turn on when we leave the room 3 if we shortly push three times then we will enter a mode of turning on off the function of auto turning lights on in a room It will automatically turn on lights if the room goes dark for five seconds If someone is inside people register shows more than ...

Page 10: ...n for 6 seconds Proposition of programming the function for the switch mounted inside the room activate functions 3 6 7 Proposition of programming the function for the switch mounted inside the bathroom activate functions 7 8 Proposition of programming the function for the switch mounted inside the washroom activate functions 6 8 Proposition of programming the function for the switch mounted insid...

Page 11: ...on the doors Use screws or double sided tape located on the elements Fig 15 Numeration of additional element sockets for the connection of optional outside elements The optional outside element socket is equipped with 8 contacts used for plugging wires in Users can expand the device by additional functions that increases the use of the Luno5 device The connection of additional devices should be do...

Page 12: ...chassis inputs marked by digit 2 or 6 Fig 16 An example of a device placement with a multiple door room additionally connect both clamps to no 6 Combining two Luno5 devices enables the transfer of data from a second device to the first Luno5 device fig 16 The manner of connecting the two devices is shown in figure 17 This function is useful when a room can be accessed by more than one door Batten ...

Page 13: ...f activity the lights will turn off and the people register won t be reset The connection of a motion sensor also enables automatically turning the lights on when at least 3 seconds of the room being dark and the sensor detects motion If the motion sensor has regulation then it should have set its output activity after detecting movement for 2 4 seconds If the user does not have a motion sensor co...

Page 14: ...sor contact is attached or can be bought via sklep eledo pl as additional equipment The manner of an additional door opening sensor connection is shown in figures 20 and 21 The contact sensor needs to be placed on the door frame preferably in an upper part of the frame from the hinge side Magnets that cooperate with the sensor need to be placed on the door so after its closed it will be located ne...

Page 15: ...and auto mode is on the symbol is not illuminated Solution Check if the light intensity sensor is set correctly The device checks the level of brightness near the switch and automatically turns the lights on only when the room is dark If the light coming from a sensor is shown in figure 5 is too bright then the device will decide that there s no need to turn the lights on The simplest test is remo...

Page 16: ...lit stable and fully fade during walking between the sensors You can also check the accuracy of sensors installed by mutually pushing the and buttons After pushing release button and keep pushing the button If the display flashes with a digit of 1 2 or 3 3 worse parameters it means that the sensors are properly mounted Improper placement of sensors can cause miscounts Improper placement of sensors...