Luno5 light switch manual
www.eledo.pl
12
Destination of additional element socket clamps (fig 15). Clamp numbers, functions and detailed descriptions:
-
8
"
Data output
”
Sends informati
on about users coming through doors
. The output is used f
or connection to another Luno5
device that works in a multiple door room
(it needs t
o be connected by a two-core cable to
"
7
” clamp
of the other device handling
the multiple door room
). Additi
onally, devices have to be connected to chassis inputs marked by digit
"2
”
or
"
6”.
Fig. 16. An example of a device placement with a multiple d
oor room
(additi
onally connect both clamps to no 6
).
C
ombining two Luno5 devices enables the transfer of data from a second device to the first Luno5 device
(fig. 16).The manner
of
connecting the two devices is shown in figure
17. This functi
on is useful when a room can be accessed by more than one door
.
Batten clamp marked "8 Output
” can be also used f
or cooperation with an additional switch that enables automatically turning on
music, heating and A/C on and off when a user is inside the room
.
Fig. 17. The connecti
on of
Luno5 devices with a r
oom with two or more entrances
.