background image

 

 

Page 20 of 20                                                                                                                      M7759   Issue 3.0 

 

 

 
 
13. EC DECLARATION OF CONFORMITY. 
 

CE marked products and associated accessories covered by this Instructions book conform to the 
essential requirements of the following directives: 

 
 
 

EMC Directive.  

 

Low Voltage Directive.  

 

A full copy of the EC Declaration / Conformity document can be obtained from the manufacture at the 
email address [email protected] 

 

 

 

 

 

 
 

 

 

 

 
 
 
 
 
 
 
 

 
 

Electrothermal. 

Electrothermal House. 
Unit12A, Purdeys Way. 
Purdeys Industrial Estate. 
Rochford, 
Essex.  SS4 1ND 
Great Britain. 
Tel +44(0)1702 303350 
Fax+44(0)1702 468731 
 
Email: 

[email protected]

  

Http  

www.electrothermal.com

 

 

  

For the America’s and Canada, contact: 
Techne Incorporated,

 3 Terri Lane, 

Suite 10 Burlington, NJ 08016 USA. 
Toll free:800-225-9243Tel: 609-589-2560 
Fax: 609-589-2571 
Email

[email protected]

 

Http 

www.techneusa.com 

 

 

        
 

 
 
 
 

                                                                                          

 2011 Electrothermal. All rights reserved. 

 

Printed in Great Britain 

 

 
 
 
 
 
 

 

Distributors Stamp 

Summary of Contents for MC227

Page 1: ...Page 1 of 20 M7759 Issue 3 0 MC227 MC228X1 CONTROLLER INSTRUCTION BOOK ...

Page 2: ...e Page 17 The copyright of this instruction book is the property of Electrothermal This instruction book is supplied by Electrothermal on the express understanding that it is to be used solely for the purpose for which it is supplied It may not be copied used or disclosed to others in whole or part for any purpose except as authorised in writing by Electrothermal Electrothermal reserve the right t...

Page 3: ...ontroller 115V AC 1 2 This series of Power controllers have been designed to regulate the power input to laboratory heating equipment These controllers can be mounted on a standard 12mm dia scaffold or retort stand they can also be wall mounted using mounting bracket or stand directly on the bench ...

Page 4: ... injury to one s self or other people The Responsible Body and the Operator should read and be familiar with this Instruction book in order to preserve the protection afforded by the equipment To prevent injury or equipment damage it is the manufacturer s recommendation that all persons using this equipment are suitably trained before use 2 2 Symbols Defined Caution risk of danger See note or adja...

Page 5: ...pply voltage is correctly earthed grounded in accordance with current area legislation Do not install or remove any heating apparatus from the controller whilst power is applied 3 2 General safe Operating Practice Always follow good laboratory practice when using this Equipment Give due recognition to your company s safety and legislative health safety procedures and all associated legislation app...

Page 6: ...able low flash point substances away from heating apparatus Do not operate or handle any part of this product with wet hands Keep the Mains Plug and Lead set cable away from the heating apparatus being controlled Refer to Instructions book for the resistive load of equipment to ensure controller is suitable for application See sub section 8 1 Always observe the Manufactures operating and safety in...

Page 7: ...x1 has a hard wired input Contents Item Description Qty 1 MC227 MC228X1 Control unit 1 2 Moulded mains cord and plug set Input Lead may be different to illustration 1 3 Instructions book this document 1 4 Wall fixing Bkt and screws x 2 per bag 1 For future reference please record your products Serial and Model Numbers Serial Number Model Number ...

Page 8: ...e only the correct rated mains input fuses are fitted Where applicable ensure the correct mains cable fuse if fitted See Technical Information Section 8 of this Instruction book 5 5 Check the voltage on the product data label of this unit Ensure the rating conforms to your local supply If an 115V product is used in a 230V supply area then a 230 115V transformer must be installed between the 230V m...

Page 9: ...Equipment Directive WEEE Please contact your distributor supplier for further information For end users outside of the EU consult applicable regulations 6 4 This product should only be dismantled for recycling by an authorised recycling company This product and accessories must be accompanied by a completed Decontamination Certificate prior to any disposal Copies of the Certificate are available f...

Page 10: ...mp Amber 4 Regulator control knob 5 Mains output connection to appliance 6 Refer to instructions book 7 Fuse holder See section 8 11 for further information 8 Rod support clamp 9 Support clip 10 Dataplate label See for correct voltage type Check the Dataplate label and ensure your mains electrical supply voltage is compatible with this product 7 2 Connect the IEC output plug from the controller to...

Page 11: ...at power is being supplied to the mantel heating tape or cord etc The frequency of the pulse will increase as the regulator control knob setting is increased At maximum setting the amber neon will be continually illuminated 7 5 When your process is complete switch off the controller and disconnect it from the mains electricity supply 7 6 For safe operating practice always refer to the Instruction ...

Page 12: ...d moulded IEC plug and lead set cable Europe AZ6747 3 core earthed ground 2 meters long Moulded IEC plug and Lead set supply cord H05 V V F Replace only with equivalent cable Mains cord and moulded IEC plug and lead set cable USA AZ6746 3 core earthed ground 2 meters long Moulded IEC plug and Lead set supply cord SJT VW 1 105 Replace only with equivalent cable Mains cord and moulded IEC plug and l...

Page 13: ...eliable service Contamination or general misuse will reduce the effective life of this product and may cause a hazard Maintenance for the unit should include Periodic electrical safety testing an annual test is recommended as the minimum requirement Regular inspection for damage with particular attention to the mains lead and plug set Routine cleaning of the equipment should be undertaken using a ...

Page 14: ...Before using any cleaning or decontamination method the Responsible Body should check with the manufacturer the proposed method will not damage the equipment Prior to further use the Responsible Body shall check the electrical safety of the unit Only if all safety requirements are met can the unit be used again The above procedure is intended as a guide Should spillage occur with a toxic or hazard...

Page 15: ...d support in using this product please contact at the following address Electrothermal Electrothermal House Unit12A Purdeys Way Purdeys Industrial Estate Rochford Essex SS4 1ND Great Britain Tel 44 0 1702 303350 Fax 44 0 1702 468731 E Mail info electrothermal com ...

Page 16: ...0A AZ9034 10 Energy Regulator 230V SA58121 1 Energy Regulator 115V SA133211 1 AZ6704 1 Mounting Bracket Kit Mains cord and moulded IEC plug and lead set UK 230V AC AZ9165 1 Mains cord and moulded IEC plug and lead set USA 115V AC AZ6746 1 Mains cord and moulded IEC plug and lead set Europe 230V AC AZ6747 1 Mains cord and moulded IEC plug and lead set UK 230V AC AZ9165 1 ...

Page 17: ...estions by deleting YES NO as applicable and by providing details in section 2 below A Blood body fluids Pathological specimens YES NO Provide details if YES B Biodegradable material that could become a hazard YES NO Provide details if YES C Other biohazard YES NO Provide details if YES D Chemical or substances hazardous to health YES NO Provide details if YES E Radioactive substances State name s...

Page 18: ...Page 18 of 20 M7759 Issue 3 0 12 NOTES ...

Page 19: ...Page 19 of 20 M7759 Issue 3 0 ...

Page 20: ... address info electrothermal com Electrothermal Electrothermal House Unit12A Purdeys Way Purdeys Industrial Estate Rochford Essex SS4 1ND Great Britain Tel 44 0 1702 303350 Fax 44 0 1702 468731 Email info electrothermal com Http www electrothermal com For the America s and Canada contact Techne Incorporated 3 Terri Lane Suite 10 Burlington NJ 08016 USA Toll free 800 225 9243Tel 609 589 2560 Fax 60...

Reviews: