ElectroSteam LG-10 series User Manual Download Page 26

HIGH PRESSURE

DRAWING TITLE:

MODEL UNIT:

DWG NO.:

DRAWN BY:

09-12-07

CHRISTOPHER FERRARA

DECRIPTIONS:

09-12-07

09-12-07

09-12-07

SAL NEGRO

CHRISTOPHER FERRARA

JOHN PARDINI

CHECKED:

ENGINEER:

APPROVED:

-

-

LG 10-30

LG (H)

121-010-030-111200

This drawing and all information therein are the property of Electro-Steam Generator Corp. and shall not be disclosed, 

in whole or in part, to any third party without prior permission of Electro-Steam Generator Corp.

PC BOARD

L1

L2

NO

COM

NC

RESET

G

G

L

LLCO

H

COM

NC

NO

ON/OFF

TOGGLE

SWITCH

T1

T2

T3

L3

L2

L1

CONTACTOR

HIGH VOLTAGE IN

208-600V

120V IN

GRND

RED

OPTIONAL

MANUAL LOW-

WATER RESET

RED

BLK

GRN

BLK

RED

YEL

BLUE

RED

RED

YEL

YEL

YEL

BLK

BLK

BLK

B
C

GRN

RED

WATER LEVEL

PROBES

A

G

1/4HP PUMP & MOTOR

HIGH PRESSURE ONLY

WATER SOLENOID

YEL

BLK

BLK

YEL

BLK

YEL

NO

C

DUAL PRESSURE

CONTROLS

NO

PPL

NC

C

BLUE

NC

BLUE

BLUE

BLUE

SHEET: 1 OF 1

SCALE: N/A

26 of 30

A

C

G

B

PROBE LENGTHS

Summary of Contents for LG-10 series

Page 1: ...BEFORE OPERATING All steam boilers are built in accordance with ASME miniature boiler code NOTE It is the responsibility of the installer to conform to any state or local codes If further inspection f...

Page 2: ...ORE USE CAUT ION O H T U CA O T I N THROW OFF MAIN POWER SWITCH BEFORE WORKING ON ELECTRICAL CABINET WARNING The following labels have been placed on this boiler for YOUR SAFETY Failure to observe the...

Page 3: ...BER CLEANING CHEMICAL TREATMENT 14 15 3 6 PRESSURE CONTROL DATA SHEET 16 3 7 SETTING THE PRESSURE CONTROLS 17 18 4 CALCULATIONS DATA SHEETS 19 21 4 1 HEATER POWER VOLTAGE RATINGS 19 4 2 TOTAL POWER RA...

Page 4: ...e around this unit must not exceed 105 F 1 1 INSTALLATION INSTRUCTIONS CLEANER PORTABLE Set STEAM GENERATOR on level floor and attach Solution Bucket 25 into the 2 predrilled holes on the rear of gene...

Page 5: ...KEY PART NO 506500 238100 2 1 a Magnet Spring f Magnet e Magnet Cap d Magnet Cover c Washer b j Lock Washer Not Shown Thumb Screw Screw k m U Clamp Z Bracket h i Armature Spring Diaphram Armature Valv...

Page 6: ...ixer on side of Solution Bucket 25 opposite the Water Inlet 6 and Steam Out 16 Tighten Thumbscrews 6m 6 Attach Discharge Tube Assembly 16 to bottom of Eductor Body Only 14s Push tight on flange 7 Remo...

Page 7: ...lectro Steam Generator Corp 1 2 INSTALLATION INSTRUCTIONS SOLUTION MIXER OPTIONAL Continued 7 of 30 2 HOSE USED TO CONNECT WATER INLET OF SOLUTION MIXER TO INCOMING WATER CONNECTION SOLUTION INLET MET...

Page 8: ...d at this time you may need to press the Safety Reset 13 If your generator is required to have a Manual Low Water Reset MLWR 3 it must be pushed it at this time to engage the contactor s 6 Once genera...

Page 9: ...placed STEAM GUN OPERATION NOTE Refer to Steam Gun Parts Legend for interpretation of lettered items 1 The special Siphon Steam Gun Deluxe gun Standard Heavy Duty Optional is equipped with Steam I and...

Page 10: ...nly a recommendation You may go higher or lower but higher is always better WARNING HOT WATER and STEAM under HIGH PRESSURE can lift drain pipes right off the ground and cause SERIOUS INJURY Make sure...

Page 11: ...ke sure the steam out and drain valves are open to assure chamber will remain depressurized DO NOT touch probes with your bare hands while HOT and be cautious of escaping steam from probe holes while...

Page 12: ...AUGE FITTINGS to remove GLASS GAUGE 2 Slip a new RUBBER WASHER on the new GLASS GAUGE about an inch from the bottom 3 Now slip the following items through the top of GLASS GAUGE in the following order...

Page 13: ...d to rotate one of the GAUGE FITTINGS to remove GLASS GAUGE 2 Slip a new GLASS PACKINGS on the new GLASS GAUGE about an inch from the bottom 3 Now slip the following items through the top of GLASS GAU...

Page 14: ...JURY Make sure drain pipe is SECURE and CANNOT move The drain must be directed into a HIGH TEMPERATURE drain NO PVC 3 Remove Safety Valve 18 WARNING There MUST be NO PRESSURE in the chamber when remov...

Page 15: ...tor completely to the top with clean water and open Manual Drain 19 to flush out generator completely 14 Reinstall Safety Valve 18 and close Manual Drain 19 15 Turn on generator allowing pressure to c...

Page 16: ...Safety turns the heaters off It must be manually pushed to turn the heaters back on This lets the user know there was a problem If it is tripped the Control most likely failed PRESSURE ADJUSTING DIAL...

Page 17: ...g your two index fingers turn the PRESSURE ADJUSTMENT DIAL CLOCKWISE causing the BLACK INDICATOR LINE to move DOWN the scale To DECREASE the pressure setting turn the dial COUNTER CLOCKWISE causing th...

Page 18: ...m Out 16 somewhere between closed and open until it does 7 Pay attention to what the pressure reads when the contactor s click off If the pressure stopped BELOW 90 PSI then INCREASE the pressure setti...

Page 19: ...240 240 480 480 480 600 600 600 NOTE 380 425V heaters are not usually rated for 380 425V They are usually 208 240V heaters that have been re stamped 380 425V and wired in series 4 2 TOTAL POWER RATING...

Page 20: ...TIONS AMPS Input Voltage 208 220 230 240 380 400 415 425 440 460 480 550 575 600 LG 10 27 8 29 4 23 1 24 1 16 9 13 4 13 9 14 2 11 11 5 12 8 82 9 22 9 62 LG 15 41 6 36 37 7 39 3 25 4 21 8 22 6 23 2 16...

Page 21: ...1 12 6 13 8 15 12 6 13 8 15 LG 20 19 5 17 8 19 5 21 2 21 7 19 7 21 2 22 2 16 4 17 9 19 5 16 4 17 9 19 5 LG 25 23 6 26 4 23 25 26 3 29 1 24 9 26 1 21 23 25 21 23 25 LG 30 29 3 32 7 26 9 29 3 32 5 27 1...

Page 22: ...OFF Switch 3 Manual Low Water Reset MLWR Optional 5 Water Level Probes 6 Water Inlet 3 8 Y Strainer 7 3 8 Water Solenoid 8 1 4 HP Pump Motor 9 1 2 Check Valves PARTS LEGEND LG C PORTABLE 18 13 12 19 1...

Page 23: ...LEVER WITH BUTTON 0014058 REAR HANDLE 1 4 UNION FEMALE END 0018058 A DESCRIPTION REF ELECTRO STEAM PART NUMBER N M K L J I G H F D E SUCTION STRAINER C B 0014041 CONNECTS TO STEAM OUT 16 NOTES TO SOLU...

Page 24: ...S P1 R1 R2 R3 R4 R5 NOT SOLD SEPARATELY NOT SOLD SEPARATELY NOT SOLD SEPARATELY NOT SOLD SEPARATELY P2 GRIP SPACER 7D FLARE NOZZLE 10 STEAM HOSE 1 4 SOLUTION VALVE 1 2 HOSE CLAMP 10 DETERGENT HOSE I G...

Page 25: ...GINEER APPROVED PORTABLE LG 10 30 INSTALLATION DATA LG C PORT 421 010 030 000306 This drawing and all information therein are the property of Electro Steam Generator Corp and shall not be disclosed in...

Page 26: ...or in part to any third party without prior permission of Electro Steam Generator Corp PC BOARD L1 L2 NO COM NC RESET G G L LLCO H COM NC NO ON OFF TOGGLE SWITCH T1 T2 T3 L3 L2 L1 CONTACTOR HIGH VOLTA...

Page 27: ...CIRCUIT BREAKER 1 13069 75AMP CONTACTOR 3 10039 6 5KW 208V HEATERS 3 10009 6 5KW 230V HEATERS or or 3PH 30KW 380 415V 1 26138 3POLE 60AMP CIRCUIT BREAKER 1 13069 75AMP CONTACTOR 3 10013 8 33KW 208V HE...

Page 28: ...0V 1 26115 2POLE 40AMP CIRCUIT BREAKER 1 13069 75AMP CONTACTOR 3 10002 5KW 480V HEATERS 1PH 25KW 440 480V 1 26119 2POLE 63AMP CIRCUIT BREAKER 1 13069 75AMP CONTACTOR 3 10014 8 33KW 480V HEATERS 1PH 20...

Page 29: ...NEGRO DRAWN BY CHECKED CHRISTOPHER FERRARA CHRISTOPHER FERRARA MODEL UNIT 8 33 9 75KW HEATERS CAN BE JUMPERED IN EITHER POSITION 29 of 30 3PH 30KW 550 600V 1 13069 75AMP CONTACTOR 1 13056A 60AMP 600V...

Page 30: ...Purchaser agrees to indemnify the Seller in like manner of the claim or suit and c purchaser provides all information and assistance to Electro Steam Corporation at purchaser s expense as is reasonab...