4.3) AMPERAGE CALCULATIONS
The
INPUT VOLTAGE, PHASE, TOTAL POWER RATING,
and
HEATER
VOLTAGE RATING
are used to calculate the amperage.
NOTE:
380-425V heaters are not usually rated for 380-425V. They are usually 208-240V heaters
that have been re-stamped 380-425V and wired in series.
FORMULAS TO CALCULATE AMPERAGE
THREE PHASE
SINGLE PHASE
208-240V & 440-600V
380-425V
(using 208-240V heaters)
208-240V &
440-600V
380-425V
(using 208-240V)
Not possible with
odd number of
heaters
DEFINITIONS:
I = Amperage
V
I
= Input Voltage
P
T
= Total Power Rating
V
H
= Heater Voltage Rating
THREE PHASE AMP DRAW CALCULATIONS (AMPS)
Input Voltage
208 220 230 240 380 400 415 425 440 460 480 550 575 600
LG-10
27.8
29.4
23.1
24.1
16.9
13.4
13.9
14.2
11
11.5
12
8.82
9.22
9.62
LG-15
41.6
36
37.7
39.3
25.4
21.8
22.6
23.2
16.5
17.3
18
13.2
13.8
14.4
LG-20
54.1
46.8
48.9
51.1
33
28.4
29.4
30.1
21.5
22.5
23.5
17.2
18
18.8
LG-25
65.6
69.3
57.6
60.1
39.9
42
34.7
35.5
27.6
28.8
30.1
22.1
23.1
24.1
LG-30
81.2
85.9
67.4
70.4
49.4
39.1
40.6
41.5
32.3
33.7
35.2
25.8
27
28.1
SINGLE PHASE AMP DRAW CALCULATIONS (AMPS)
Input Voltage
208 220 230 240 380 400 415 425 440 460 480 550 575 600
LG-10
48.1
50.9
39.9
41.7
19.1
20
20.8
15.3
16
16.7
LG-15
72.1
62.4
65.2
68.1
28.6
29.9
31.3
22.9
24
25
LG-20
93.8
81.1
84.8
88.5
37.2
38.9
40.6
29.8
31.1
32.5
LG-25
114
120
99.8
104
47.7
49.9
52.1
38.2
39.9
41.7
LG-30
141
149
117
122
Not possible with odd
number of heaters
55.9
58.4
60.9
44.7
46.7
48.8