ELECTRIC BICYCLE METER S-LCD3 Product User Manual
- 33 -
C12 parameter setting interface
C12 is controller minimum operating voltage adjustment mode (tiny adjustment of
voltage shortage). The default value is 4, and the setting range is 0-7, hold
button
(UP)
or
button
(DOWN)
shortly for selection.
C12 parameter definition table
:
C12 value
Minimum Voltage(V)
24V Controller
36VController
48VController
0
Default value-2V
Default value-2V
Default value-2V
1
Default value-1.5V
Default
value-1.5V
Default
value-1.5V
2
Default value-1V
Default value-1V
Default value-1V
3
Default value-0.5V
Default
value-0.5V
Default
value-0.5V
4
Default value 20V
Default value
30V
Default value
40V
5
Default value+0.5V
Default
value+0.5V
Default
value+0.5V
6
Default value+1V
Default value+1V
Default value+1V
7
Default value+1.5V
Default
value+1.5V
Default
value+1.5V
C12 default value is 4, namely, controller minimum operating voltage (voltage
shortage value); when setting is 5, the default value plus 0.5V, when setting is 4, the
default value minus 0.5Vand so on.