background image

 

 

5

Manual SP-44

 

- BLOWER POTENCY - this function is 
used to set the potency with which the 
blower insufflates air to the hearth.

BLOWER POTENCY

BLOWER POTENCY

SUSTAINING
OPERATION

SUSTAIN PAUSE

SUSTAINED
PAUSE

SUSTAINED
OPERATION

SUSTAINED
OPERATION

BLOW DELAY

70%

15 MIN.

30 SEC.

- BLOW DELAY - this function allows to 
extend the blower operation time in 
relation to the conveyer in suspend 
mode.

BLOW DELAY

10 SEC.

- SUSTAINED OPERATION - this 
function allows to set operation time of 
the blower and the conveyer in the 
suspend mode.

- SUSTAIN PAUSE - this function allows 
to set an intermission between turning 
on the blower and turning on the 
conveyer in sustain mode.

- SUSTAINING OPERATION

-H.W.S.T. HISTERESIS - this function 
allows setting usable water hysteresis, 
which creates a delay powering on the 
hot water storage tank by pre-defined 

O

temperature: 2 C hysteresis, expected 

O

temperature is 50 C the pump will be 
turned on, when the temperature of the 

O

usable water reaches 48 C

H.W.S.T.
HISTERESIS

H.W.S.T.
HYSTERESIS

O

2 C

- C.H. vs.H.S.W.T. PRIORITY

C.H. vs. H.W.S.T.
PRIORITY

Summary of Contents for SP44

Page 1: ...MICROPROCESSOR BOILER HEATER MANUAL WARRANTLY CARD CONTROLLERS FOR CENTRAL HEATING BOILERS TEMPERATURE CONTROLLER SP44 ...

Page 2: ...D Display 3 Control lights 4 Control buttons 5 Blower switch ON light 6 Central Heating C H switch ON lamp 7 Hot Water Storage Tank H W S T switch ON lamp 8 Floor Heating Pump switch ON lamp 9 Conveyor switch ON lamp The view of the controller with its functionalities marked 1 2 3 4 5 6 7 8 9 ...

Page 3: ...e temperature set 2 Maintenance mode air temperature is greater than the temperature set The controller allows keeping the temperature set at the hot air outlet 3 Controller handling In order to turn on the controller you need to press the ENTER button After turning it on you will see its main page on the display which shows the following data Achieved and pre set central heating temperature Achie...

Page 4: ...s function is used to kindle the cauldron it allows independent star of the blower exhaust conveyer and both pumps MANUAL START BLOWER Pressing the ENTER button turns ON or OFF one of the exists Using buttons and we can change exists which we intend to turn ON or OFF With the EXITbutton we can go back to settings menu FUEL SUPPLY this function is used to set the time when the fuel is supplied by t...

Page 5: ...s function allows to set operation time of the blower and the conveyer in the suspend mode SUSTAIN PAUSE this function allows to set an intermission between turning on the blower and turning on the conveyer in sustain mode SUSTAINING OPERATION H W S T HISTERESIS this function allows setting usable water hysteresis which creates a delay powering on the hot water storage tank by pre defined O tempera...

Page 6: ...ON CLOCK optional this function is used to set working areas and time as well as to set the time when the circulation pump turn on The controller has three working areas Mon Fri ans Sat Sun Each has three modes for power on times CIRCULATION CLOCK TURN ON CIRCULATION it is used to turn ON OFF that functionality TURN ON CIRCULATION Mon Fri and Sat Sun CIRCULATION with the ENTER button we enter the ...

Page 7: ... meaning the type of fuel and type of installation At first the blower potency should be set we need to remember that too high power will cause the coal to slag and too low power will leave unburned coal in the ashpan Once the blower is set we need to set fuel supply It has to be set in a way that allows the cauldron to reach the desired FLOOR HEATING the controller includes foor heating pump contr...

Page 8: ...d to set time which measured after reaching the temperature lower that the one set at extinguishing temperature point Once the set time passes the controller shuts down the cauldron and communicates lack of fuel EXTINGUISHING TEMPERATURE this function is used to set central heating temperature below which the time set at the extinguishing time is being counted down Once the temperature is below th...

Page 9: ... function is used to set 100 operational power of blower with a parameter between 1 and 5 sec which has to be adjusted due to temporary power losses of the fan If we see that the fan works incorrectly during the startup it cannot start we should increase the startup time ROOM CONTROLLER it is possible to connect room contoller to the main controller It controls the central heating pump There is a ...

Page 10: ...ss I ź Electrical security 8A ź The controller has a function designed to protect the cauldron from o overheating over 94 C the thermostat automatically disconnects the fan circuits ź The controller has a fire sustain function after reaching previously set temperature of the cauldron it turns the fan on occasionally and supplies fuel via the helix conveyer simultaneously ź The controller has a func...

Page 11: ...Sustaining constant temperature of the central heating cauldron set by the user by automatic fuel supply and turning on the blow in to the hearth 2 Automatic turning on of the central heating floor heating and hot water tank storage pumps 3 Automatic blower switch off as well as the pumps and the conveyer once all the fuel from this bin is used 4 Constant temperature readings 6 Error messages Error ...

Page 12: ... should be checked ź The fuse at the front side of the panel ź Check connectons and technical condition of other devices such as the blower pups and the conveyer ź Revers the controller to default settings 6 The cauldron should have reverse valves on Central Heating and hot water tank storage circuits 7 The floor heating requires fitting a three way valve on the cauldron output in order to reduce th...

Page 13: ... centre 7 Seller is obliged to fill in the warranty card on the day of giving out the equipment Warranty card which is not filled in or having any corrections or cross outs precludes exercising warranty rights 13 Warrantly card Information on utilization of electric and electronic devices This symbol placed on products or documentation attached to them informs that unserviceable electric or electr...

Page 14: ...14 Warrantly card ...

Page 15: ...15 Notes ...

Page 16: ...MANUFACTURER Electronics S C Paweł Wilgocki Piotr Wilgocki ul Moczydło 10a 30 698 Kraków tel 012 650 47 90 fax 012 650 47 91 e mail biuro electronics net pl ...

Reviews: