5
Manual SP-44
- BLOWER POTENCY - this function is
used to set the potency with which the
blower insufflates air to the hearth.
BLOWER POTENCY
BLOWER POTENCY
SUSTAINING
OPERATION
SUSTAIN PAUSE
SUSTAINED
PAUSE
SUSTAINED
OPERATION
SUSTAINED
OPERATION
BLOW DELAY
70%
15 MIN.
30 SEC.
- BLOW DELAY - this function allows to
extend the blower operation time in
relation to the conveyer in suspend
mode.
BLOW DELAY
10 SEC.
- SUSTAINED OPERATION - this
function allows to set operation time of
the blower and the conveyer in the
suspend mode.
- SUSTAIN PAUSE - this function allows
to set an intermission between turning
on the blower and turning on the
conveyer in sustain mode.
- SUSTAINING OPERATION
-H.W.S.T. HISTERESIS - this function
allows setting usable water hysteresis,
which creates a delay powering on the
hot water storage tank by pre-defined
O
temperature: 2 C hysteresis, expected
O
temperature is 50 C the pump will be
turned on, when the temperature of the
O
usable water reaches 48 C
H.W.S.T.
HISTERESIS
H.W.S.T.
HYSTERESIS
O
2 C
- C.H. vs.H.S.W.T. PRIORITY
C.H. vs. H.W.S.T.
PRIORITY