4.3: Programming Parameters
The following section lists the programming parameters which are used to configure the
system. For a listing of the default parameters please contact your local dealer.
Address 00: Communication Attempts
The control panel’s attempts to communicate with the central station are organized in
rounds. A communication round is a set of dialing attempts. If the panel does not
succeed in sending the event message to the primary number within this number of
attempts, the backup number is dialed the same number of times. A new round will begin
30 minutes after the last dialing attempt. The number of communication rounds is defined
in the first digit of this address. The number of dialing attempts in each round is defined
in the second digit.
Note: To Disable Communications, enter 00 at this address.
First Digit:
Communication Rounds
Enter a value between 1 – F
(F = 15 communication rounds)
Second Digit:
Dialing Attempts
Enter a value between 1 – F
Address 01: Miscellaneous
This address offers a number of options for the system’s setup. Enter 5 digits at this
address according to the following:
Fifth Digit:
P Key Alarm
0 - Audible
1 - Silent
First Digit:
Keypads
0 - No Keypads
1 - One Keypad
2 - Two Keypads
3 - Three Keypads
Third Digit:
Tamper Zone Definition
0 - Arm/Disarm Keyswitch
1 - Tamper Zone
Second Digit:
Keyswitch Function
0 - Latching
1 - Momentary
Fourth Digit:
E Key Alarm
0 - Audible
1 - Silent