-8-
+
3
7
4
8
5
9
6
LOAD
(100mA max.)
AUX
PGM
2.3: Terminal Connections
15-16.5VAC Input
(J1) Terminals 1 & 2:
Connect a 15VAC transformer
rated at 22-30VA, using 18 AWG wire.
Auxiliary Power Output
(J1) Terminals 3(+), 4(-):
The auxiliary power output connections supply power to
keypads and peripheral units such as detectors and other powered sensors.
Keypad Data Bus Connections
(J1) Terminals 5 & 6:
Connect up to three LED keypads to terminals 5 (K2), and 6 (K1).
Make sure that the wires are connected to the corresponding terminals on the keypad –
see 2.4: Mounting the Keypad.
Bell Power Output
(J1) Terminals 7(+), 8(-):
Connect these terminals to supply
power to the bell. The bell power output supplies AUX power,
rated at 600mA max.
Bell Supervision (USA hardware only)
The bell connections must be terminated by a 2.2K ¼W resistor
as shown in Figure 2.1.
PGM Programmable Output
(J1) Terminal 9:
The PGM output switches
to ground when activated, enabling the
connection of additional system status
indicators. Connect the PGM output as
shown in the Figure 2.2.
Tamper Zone/Keyswitch Connections
(J1) Terminal 10:
Connect a tamper switch or ON/OFF
keyswitch to terminals 10(+) and 12(-).
Note: If neither the tamper zone nor keyswitch are used, short
terminal 10 to 12 and define this zone as Tamper Zone at
Address 01.
Zone Connections
(J1) Terminals 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21 & 22:
ZONE 1: Terminals 11(+) & 12(-)
ZONE 5: Terminals 17(+) & 18(-)
ZONE 2: Terminals 13(+) & 12(-)
ZONE 6: Terminals 19(+) & 18(-)
ZONE 3: Terminals 14(+) & 15(-)
ZONE 7: Terminals 20(+) & 21(-)
ZONE 4: Terminals 16(+) & 15(-)
ZONE 8: Terminals 22(+) & 21(-)
10
11
12
+
Tamper Switch or
ON/OFF Keyswitch
2.2K
7
8
+
Figure 2.1: Bell
Supervision Connections
Figure 2.2: PGM Output Connections
Figure 2.3: Tamper Zone/
Keyswitch Connections