Temperature:
Input Range: 0 to 2.5 Volts Differential
Input Impedance: 12.1K Ohms on each input to ground
Sensitivity: 9.537uV per count.
Notes:
* Any Temp Channel may be used to measure any thermocouple probe or any device outputting a voltage.
In this way many different types of function may be monitored through a temperature channel. See an
E.I. price sheet for a list of modules available.
* A Reference junction is provided to accommodate TC probes. Temp channel 8 is closest to the “Ref
Diode” and is best used for measuring OAT.
Resistive Fuel Level:
The resistive and capacitive inputs share channels. Only one input type should be used per
channel.
Input Range: 0 to 18 Volts single-ended input.
Input Impedance: 14.4K Ohms.
Sensitivity: .07169mV per count when set for non ratiometric measurement.
Notes:
* The Resistive Fuel Level inputs may be used to monitor other functions or annunciators.
* When monitoring a resistive probe a RFLM-4-12 or -24 module will be required (see E.I. price sheets).
Also, measurements are made ratiometric to the bus voltage.