10.4.2 Batch Mode :
1] Power On the instrument. Display will show
2] Press key. Display will show
3] Press key. Display will show
Press key. Now the display will blink. Press key to change Alarm Type LOW, HIGH
and BATCH. Press key to store alarm type.
4] Now, Display will show
Press key. Display will blink. Enter the desired value one by one using & key.
Press key to store the value.
5] Display will show
Press key. Display will blink. The key is used to change Alarm type.
Press key to store alarm type condition.
6] Press twice key. Go to RUN mode.
P
Program
Alarm
Alarm Type
BATCH
Set batch
0010.00 m3
Alarm relay
Failsafe
P
10.5 Configure Instrument Method :
10.5.1 Program Parameter :
System offers user to set flow unit, Totaliser unit, Decimal point, max flow range,
Low flow cut o fflimit, damping factor, etc.
1] Power On the instrument. Display will show
2] Press key. Display will show
Then press key display will show
3] Press key. Display will show
Enter the password 1234 using & key.
4] Press key. Display will show
Press key display will show
Press key. Display will blink. The key is used to change Engg. unit.
Press key to store Engg. unit.
P
Program
Alarm
Configure
Instrument
Enter Password
0000
Flow Engg. Unit
m3
Program
Parameter
F00034.9 m3/Hr
F688465.68 Ltr L
F00034.9 m3/Hr
F688465.68 Ltr L