ELECTRONET
UM-ELMAG 200-R3
PAGE 12 OF 34
b) Cable Glanding For Non Armoured
Cable :
Assembly Method :
1) Grease all the threads.
2) Thread in the cable, the tighten nut (1), the adjustment bushing (2) and body gland
(4) with the flameproof gasket (3) toward of the side of the other part of the cable
gland.
3) Thread the body gland at the entry with the appropriate wrench until it has been
adjusted definitively.
4) Thread all the parts with a considerable adjustment (with the appropriate wrench).
5) In cases of cable glands for “e” protection or weather proof, add the watertightness
washer.
9.3 Safety Precautions :
a) Flow meter must be properly grounded or earth according to local electric codes.
b) Install signal wiring separate from the high voltage power cable.
c) After termination cabling , fit back cover properly to maintain IP certification.
Tighten nut (1)
Adjustment bushing (2)
Flame proof gasket(3)
Body gland(4)
Water tightness washer (5)
Tighten nut (1)
Adjustment bushing (2)
Body gland with
flame-proof gasket (3-4)
Water tightness washer (5)