22
Boost Pump
Figure 11: Boost Pump
An
important
Consideration for mounting the components in the pre-filter and boost pump
assembly is the
accessibility
both for visual inspection and changing out the pre-filter
elements. The boost pump
MUST
be mounted
below
the waterline, mount the boost pump
in a location that will provide adequate
cooling
air volume
.
D
O NOT LOCATE THE
BOOST PUMP NEAR OTHER HOT EQUIPMENT
.
U
SE ONLY
10
GAUGE OR LARGER
WIRE
.
A
maximum
rated 5Amp, 12 VDC fuse or breaker is required for the installation
of the boost pump circuit protection. The wiring color code is Red for POS, Black for
Negative.
The pre-filter assembly can be mounted above or below the
waterline
. Keep in mind that
access
will be needed to the filter assemblies for changing the pre-filter elements
periodically when they become fouled by particulate matter in the incoming sea water. The
pre-filter assembly is designed to be mounted
vertically
using the included mounting
bracket. Be sure to leave enough room below the assembly to
allow
for opening of the pre-
filter housing for filter element replacement, which is approximately 3 inches. A good
location would also be one where the pre-filter assembly can be easily viewed, for a quick
visual
observation on the state of the filter elements.
The inlet and outlet connection on the
pre-filter assembly and boost pump are all
identified
in Figures 10 and 11 detailing where
the tubing runs should be directed.
Summary of Contents for AQUAMAAX MODULAR SERIES
Page 13: ...13 Figure 5 Process Flow Diagram ...
Page 18: ...18 Control Panel Figure 8 Control Panel Front View ...
Page 19: ...19 Control Panel Backside Figure 9 Control Panel Back View ...
Page 21: ...21 Pre filter Assembly Figure10 Pre filter Assembly20 micron 5Micron ...
Page 24: ...24 Figure 13 115 VAC Motor Wiring Installation Diagram ...
Page 25: ...25 Figure 14 DC Motor Boost Pump Wiring Installation Diagram ...
Page 26: ...26 Figure 15 DC Motor Electrical System Schematic ...
Page 27: ...27 Figure 16 Engine Driven Electrical System Schematic ...
Page 37: ...37 Auto Flush Wiring Connections ...
Page 38: ...38 Notes for your convenience ...