SOI/DT 2005-01 dmm
599 36 82-57
59/67
Alarm
Description
Possible fault
Action/machine status
Reset
E39
“HV” sensor of anti-overflow level faulty
PCB faulty.
Cycle blocked, door locked.
OFF/reset
E3A
Heating elem. relay sensing faulty
PCB faulty.
Cycle blocked, door locked
OFF/reset
E41
Door open
Door interlock faulty; wiring faulty;
PCB faulty.
Cycle paused
Start
E42
Problems of door closure
Door interlock faulty; wiring faulty;
PCB faulty.
Cycle paused
Start
E43
Interlock power supply triac faulty
Door interlock faulty; wiring faulty;
PCB faulty.
(Safety drain cycle) Cycle blocked
OFF/reset
E44
Door interlock sensor faulty
PCB faulty.
(Safety drain cycle) Cycle blocked
OFF/reset
E45
Door interlock sensing circuit triac faulty
PCB faulty
(Safety drain cycle) Cycle blocked
OFF/reset
E51
Motor power supply triac short-circuited
PCB faulty; current leakage from motor or from wiring.
Cycle blocked, door locked (after 5
attempts)
OFF/reset
E52
No signal from motor tachometric generator
Motor faulty; wiring faulty; PCB faulty
Cycle blocked, door locked (after 5
attempts)
OFF/reset
E53
Motor triac sensing circuit faulty
PCB faulty.
Cycle blocked, door locked
OFF/reset
E54
Motor relay contacts sticking
PCB faulty; current leakage from motor or from wiring
Cycle blocked, door locked (after 5
attempts)
OFF/reset
E61
Insufficient heating during washing
NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty.
The heating phase is skipped
---
E62
Overheating during washing
NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty.
Safety drain cycle – Cycle stopped
with door open
OFF/reset
E66
Heating element power relay faulty
PCB faulty; current leakage from heating element to ground.
Safety drain cycle – Cycle stopped
with door open
OFF/reset
E71
Washing NTC sensor faulty
NTC sensor faulty; wiring faulty; PCB faulty.
The heating phase is skipped
Start
E74
Washing NTC-sensor badly positioned
NTC sensor badly positioned; NTC sensor faulty; wiring faulty; PCB
faulty.
The heating phase is skipped
Start
E82
Error in selector reset position
PCB faulty (Wrong configuration data). Selector, wiring
---
OFF/reset
E83
Error in reading selector
PCB faulty (Wrong configuration data). Selector, wiring
Cycle cancelled
---
E84
"Sensing" circuit on circulation pump triac
faulty
(input signal to microprocessor always 0V or
5V)
PCB
Drain, cycle blocked (door open)
OFF/reset
E85
Circulation pump faulty
(incongruency between status of "sensing"
circuit on circulation pump and status of
TRIAC)
Circulation pump;
wiring;
main PCB
Drain, cycle blocked (door open)
OFF/reset
E91
Communication incongruence between main
PCB- display board
(versions not compatible)
Wiring faulty; Faulty control/display board
Main PCB faulty.
Cycle interrupted
---