SOI/DT 2005-01 dmm
599 36 82-57
56/67
13 ALARMS
13.1 Displaying the alarms to the user
Control of the alarm system can be configured; according to the model, therefore, some or all of the alarms
may be displayed to the user.
The following alarm families are displayed to the user:
Door not Closed
Please check
No incoming water
Check tap&Hose
No drain
Check hose/ filter
The alarms are active during the execution of the washing programme; except for the alarms
relative to the configuration and power/frequency supply which are displayed also in the selection
phase.
The door can normally be opened (except where specified) when an alarm condition has occurred on
condition that:
•
The level of the water in the tub is under a level which depends on the configuration of the appliance.
•
The temperature of the water is lower than 55°C
Certain alarm conditions require that a drain phase be performed before the door can be opened:
•
Cooling water fill if the temperature is in excess of 65°C
Drain until the pressure switch is on empty, during a max. 5 minute time.
The other alarms are not displayed to the user (the appliance stops)
The technician can display the alarm by entering the DIAGNOSTICS MODE (page 61)
13.1.1 Operation of alarms during diagnostics
All alarms are enabled during the components diagnostics phase. Moving the selector to pass from one
control phase to the other, the appliance exits the alarm condition and performs the selected phase (if the
alarm does not occur again).
13.2 Notes about some alarms
Configuration alarms
ª
E91
: the error is displayed in the LCD as E90
ª
E92
: the error is displayed in the LCD as E90
ª
E93
: the error is displayed in the LCD as E90
ª
E95
: the error is displayed in the LCD as E90
ª
EB1-EB2-EB3 alarms:
in case of problems with the power supply, the machine remains in alarm
condition till the frequency or the power supply voltage returns to correct values or the appliance
is switched off. “
EB0
” alarm family is displayed and it is not possible to enter the diagnostics or to
use “alarm fast display” mode: the alarm complete can be read only when the abnormal situation
terminated.