12.4.3 Central payment (2C)
The central payment or booking system shall transmit an active (high) signal to the machine once
permission has been granted to start the machine. The signal must remain active (high) until the
machine starts. A feedback signal will be present on connection 18 and remain active (high) whilst
the machine door is closed but the program has not started. The feedback signal is powered
by 230V or 24V from connection 19.