8.2 Replacement of the belt
Disconnect the power to the machine.
Demount the back panel.
Remove the belt (A) and put the new belt in position. Check the belt tension with a frequency
meter or similar. The frequency shall be 70 Hz ± 5. Adjust if necessary with the right screw in
the slotted hole.
A
fig.7579
⑯
Remount the back panel.
Connect the power to the machine.