7:1
438 9162-01/02
1
5861
3
5863
2
5862
A
3
5865
2
5864
X46
Steam connection
The steam supply to the machine should be fitted
with manual shut-off valves and filters to facilitate
installation and servicing.
The connection hose must be of type ISO/1307-
1983 or equivalent. Connection size at filter:
DN 15 (BSP 1/2").
Steam pressure required:
•
minimum: 50 kPa (0.5 kp/cm
2
)
•
maximum: 800 kPa (8 kp/cm
2
)
•
Remove the cover (A).
•
Mount the articulated nipple to the steam
valve.
•
Mount the steam valve on the machine.
•
Mount nipple, strainer and elbow. Note the
direction of the strainer. Mount steam hose to
the elbow.
Check that there are no sharp angles or bends
on the connected steam hose.
•
Mount the hose with wires between steam
valve and machine.
Connect wires in the steam valve.
Connect ground cable to the terminal ground
connection.
Mount the cable connector on X46 on
distribution card.
Installation
Fig.
1
Fig.
2
Fig.
3
Fig.
4
Fig.
5