Installation
28
Conversion instructions - T4530 only:
1. Disconnect the power to the dryer.
2. Open the operating panel.
. Remove nozzle (1), see Fig. 6.
4. Mount the supplied nozzle (1), see Fig. 2.
. Loosen the measuring branch screw (2) 1/4 turn; connect a manometer to the measuring
branch (2), see Fig. 6.
6. Connect the power and select a programme with heat.
. Start the dryer.
8. See nozzle pressure in Fig. 2 - set the nozzle pressure on setting screw (4) under cover
screw (), see Fig. 6.
9. Check that the gas flame burns evenly and has a bluish colour.
10. Mount the cover screw (), see Fig. 6.
11. Close the operating panel.
NOTE:
After the conversion has been carried out, the enclosed sign with the new gas type
printed on it
must
be affixed to the dryer data plate, see instructions later.
4 + 3
Fig. 6
Fig. 7
2
1
ø