- 56 -
599 51 13-50 EN
DGS-TDS-N 11.2004 C.D.
© Electrolux
10.2.3Motor
The drive motor is fastened to the tub with 4 screws.
-
Take off the rear plate; instructions 10.2.1
-
Draw off the motor plug.
-
Remove the drive belt.
-
Now unscrew the motor
Belt
Motor
Motor plug
Motor screws
10.2.4 The heating element
The heating element is inserted in the rear side of the tub and the contacts are protected by tahe clipped
cover. Tightening the pressure plate to the heating flange expands the sealing and thus fastens the
heating element.
-
Carry out an emergency drain of the appliance.
-
Take off the rear plate; instructions 10.2.1
-
Remove the cover
-
Disconnect the electrical connections
-
Untighten the flange nut to the end of the thread and press in the stud bolt with the nut
as far as to the pressure plate (sealing gets released).
-
Loosen the heating element by moving it laterally and pull it out of the tub.
Abb.: 19
Abb.: 20
cover of
heating
element
electrical
connections