Error Possible Cause or Condition
Suggested Corrective Action
70
See error 30
See error 30
71
Internal generator error, sync
(center cooking zone)
- Test cables & connections on center generator circuit board
(single).
- Replace the generator circuit board (single) in the 3 zones
induction module .
72
See error 32
See error 32
73
See error 33
See error 33
74
Internal generator error, communication
(3 zones induction module)
- Check cable between
fi
lter board X13 and generator board X10
- Replace the
fi
lter circuit board in the 3 zones induction module
- Replace generator circuit board in the 3 zones induction module
75
See error 35
See error 35
76
Communication Error in the 3 cook zones
induction module for the center cooking
zones.
- Verify all communication cables between user interface and
both induction generator modules.
- Replace the
fi
lter circuit board in the 3 zones induction module .
- Replace generator circuit board for the center cook zone in the
3 zones induction module
77
Heat sink temperature sensor break in the
3 cook zones induction module for the
center cooking zones.
- Replace generator circuit board for the center cook zone in the
3 zones induction module
80
Flash/Rom check fail (EEPROM data)
- Replace main power touch control
90
AC input voltage too high in the 2 cook
zones induction module.
- Verify AC input voltage at the cooktop input.
- Verify AC main input cables, screws and jumpers.
- Replace the
fi
lter board in the 2 zones induction module
91
Internal generator error, sync in the 2 cook
zones induction module.
- Test cables & connections on right generator circuit board.
- Replace the right side generator circuit board
92
12V on the service section too low in the 2
cook zones induction module.
- Test all cables & connections on
fi
lter circuit board in the 2
zones induction module.
- Replace the
fi
lter circuit board in the 2 zones induction module .
- Replace generator circuit boards in the 2 zones induction
module
93
5V overcurrent on the switched 5V on the
service section (2 zones induction module).
94
Internal generator error, communication in
the 2 cook zones induction module.
- Verify cable between
fi
lter board X58 and generator board X10
on the 2 zones induction module.
- Verify the heat sink thermal cutout in the 2 zones induction
module is connected and resistance is approximately 0 ohms.
- Replace the
fi
lter circuit board in the 2 zones induction module.
- Replace generator circuit board in the 2 zones induction
module
95
AC input voltage too low in the 2 cook
zones induction module.
- Verify AC input voltage at the cooktop input.
- Verify AC main input cables, screws and jumpers.
- Verify the fuse resistance is approximatively 0 ohms in the 2
zones induction module.
- Replace the
fi
lter circuit board in the 2 zones induction module
96
Communication Error in the 2 cook zones
induction module.
- Verify all communication cables between user interface and
both induction generator module.
- Replace the
fi
lter circuit board in the 2 zones induction module .
- Replace generator circuit board in the 2 zones induction module
97
Heat sink temperature sensor break in the
2 cook zones induction module.
- Replace the generator circuit board in the 2 zones induction
module
ELECTROLUX ICON 36” Induction Cooktop Error Codes