7. CONNECTION TO THE POWER
SUPPLY MAINS
FOR SERVICEMAN ONLY
Before fitting the plug in the power supply
socket, for your own safety, as already
mentioned in the previous paragraph, please
read the following precautions.
- The machine’s electrical safety is only
guaranteed when it is connected to a suitable
earth system, structured as provided by the
national safety current regulations (fig.21).
Therefore, the manufacturer cannot be held
responsible for any damage due to failure of the
grounding system of the machine.
- Always verify electrical specifications on the
data plate of each machine. Data plate
specifications always replace the information of
this manual.
- For a safe and correct installation, it is
essential to provide a suitable socket controlled
by a thermal cut-out switch whose contacts are
at least 3 mm apart, in accordance with the
current national safety regulations (see fig.21).
- Never use extensions or multiple adaptors.
- Check the power lead along its entire length to
make sure it is not crushed in any way.
- To unplug the device, first disconnect the
power supply with the switch, then grip the plug
and gently pull it out.
Important
IF THE POWER CABLE IS DAMAGED, IT MUST
BE REPLACED BY THE MANUFACTURER, ITS
AFTER SALE SERVICE OR BY QUALIFIED
PERSONNEL, TO PREVENT ANY POSSIBLE RISK.
Fig. 21
Summary of Contents for GT1 Push
Page 1: ...Data di emissione Febbraio 2019 Revisione 6 Pag 1 28 GT1 e GT2 Push Operator s manual ...
Page 22: ...Data di emissione Febbraio 2019 Revisione 6 Pag 22 28 14 WIRING DIAGRAM ...
Page 23: ...Data di emissione Febbraio 2019 Revisione 6 Pag 23 28 ...
Page 24: ...Data di emissione Febbraio 2019 Revisione 6 Pag 24 28 ...
Page 25: ...Data di emissione Febbraio 2019 Revisione 6 Pag 25 28 ...
Page 26: ...Data di emissione Febbraio 2019 Revisione 6 Pag 26 28 ...
Page 27: ...Data di emissione Febbraio 2019 Revisione 6 Pag 27 28 ...