6
FMV156EMC
Maximum
output
70% of
maximum
output
H : GND
L : -5V
H : GND
L : -5V
ON
ON
OFF
OFF
OFF
24 sec.
8 sec.
16.7 msec.
H : GND
L : -5V
7
AN3
oUt
Back light circuit (light emitting diodes) driving signal.
8
AN
IN
To input signal which communicates the door open/close information to LSI.
Door close "H" level signal (0V). Door open "l" level signal (-5V).
9-10
AN1-AN0
oUt
terminal not used.
11-13
P57-P55
oUt
terminal not used.
14
cNtR0
oUt
Signal to sound buzzer (2.0 kHz).
A: key touch sound.
B: completion sound.
15
P53
oUt
terminal not used.
16
P5
oUt
Oven lamp, fan motor and turntable motor driving signal
to turn on and off shut off relay (RY1). the square
waveform voltage is delivered to the RY1 driving
circuit and RY control circuit.
17-18
P51-P50
oUt
terminal not used.
19
P47
oUt
Magnetron high-voltage circuit driving signal.
to turn on and off the cook relay (RY). the
signals holds "l" level during microwave cooking
and "H" level while not cooking. In other cooking
modes (variable cooking) the signal turns to "H"
level and "l" level in repetition according to the
power level.
(oN and oFF times for other power level.)
0
P46
IN
Signal coming from touch key.
When either G1 line on key matrix is touched, a corresponding signal out of P0, P1,
P, P5 and P6 will be input into P46. When no key is touched, the signal is held at "H"
level.
1
P45
IN
Signal similar to P46.
When either G11 line on key matrix is touched, a corresponding signal will be input into
P45.
P44
IN
Signal similar to P46.
When either G10 line on key matrix is touched, a corresponding signal will be input into
P44.
3
P43
IN
Signal similar to P46.
When either G9 line on key matrix is touched, a corresponding signal will be input into
P43.
4
INt0
IN
Signal synchronized with commercial power source frequency.
this is the basic timing for time processing of lSI.
5
P41
oUt
terminal not used.
6
P40
IN
connected to GND through the pull-down resistor R100.
7
RESEt
IN
Auto clear terminal.
Signal is input to reset the lSI to the initial state when power is applied.
8-9
P71-P70
oUt
terminal not used.
30
xIN
IN
Internal clock oscillation frequency input setting.
the internal clock frequency is set by inserting the ceramic filter oscillation circuit with
respect to xoUt terminal.
31
xoUt
oUt
Internal clock oscillation frequency control output.
output to control oscillation input of xIN.
3
VSS
IN
Power source voltage: -5.0V.
Vc voltage of power source circuit input.
Pin No.
Signal
I/O
Description
A
B
0.1 sec.
2.0 sec.
H : GND
L : -5V
H : GND
L : -5V
16.7 msec.
During cooking
H : GND
L : -5V