TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
J
HOOD THERMAL CUT-OUT TEST
1. Disconnect the power supply cord, and then remove outer case.
. open the door and block it open.
3. Discharge high voltage capacitor.
4. A continuity check across the thermal cut-out terminals should indicate an open circuit unless the
temperature of the thermal cut-out reaches approximately 140½F(60½c) or more. At that temperature,
the contacts will close. the thermal cut-out opens automatically at approximately 113½F(45½c).
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
K
HOOD FAN MOTOR TEST
1. Disconnect the power supply cord, and then remove outer case.
. open the door and block it open.
3. Discharge high voltage capacitor.
4. If the motor does not turn, touch the FAN button once and check voltage between pins "1" and ""
(Blue and Black wires) of the 6 pin connector. If 10 Volts appear and the hood capacitor is good,
replace the hood fan assembly. If 10 Volts does not appear, check the motor circuit. the resistance
values of motor terminals are as follows:
5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.
Resistance between;
BlU (1) AND YlW (4) =
0
Ω
(Shorted)
BlK () AND YlW (4) = 60
Ω
BlU (1) AND BlK () = 60
Ω
RED(5) AND BlU (1) = 16
Ω
RED(5) AND BlK () = 10
Ω
YlW(4) AND RED (5) = 16
Ω
6-PIN coNNEctoR
oF HooD FAN MotoR
BLU BLK
YLW RED
1
2
4
5
60
Ω
102
Ω
HOOD FAN
CAPACITOR
YLW
RED
BLU
BLK
1
2
4
5
SUB
60 Hz
120 v
MAIN
Summary of Contents for FMV156EMC