Service
Manual
9406
Fault finding
The coil does not lock the door when programmer knob is turned to I.
•
Check that lamp in the red push button is lightning. If not, check that the
emergency opening is not activated.
•
Check that the coil is receiving voltage and that the plunger can move
freely. Check with a ohm-meter for interruption in the coil.
•
Check that the delay unit receives voltage.
•
Check that switch S3 in the locking unit is activated when the door is
closed and door handle is closed position.
The machine does not start in spite that the door is locked by the
coil.
•
Check that switch S4 is closed when the coil is activated.
Repairing
The door lock is an important safety device. Therefore a faulty
locking unit or delay unit may not be repaired. It shall be changed
for a new unit.
29
29. Door and safety locking device