8.
HELPFUL HINTS AND TIPS
TP – Temperature Protection
Abnormal safety cut-out
During normal operation if the temperature
exceeds the showering safety limit (49°) the
power to the elements will be removed
completely, although water will continue to
automatically restored to the settings at the
time of interruption.
Cut off the power while not in use
In normal use, it is in order to leave the water
supply permanently on to the shower unit,
but as with most electrical appliances, the
unit MUST be switched off at the isolating
switch when not in use.
It will take a few seconds for the temperature
to stabilise once changes have been made.
If restarting immediately after stopping, be
aware that a slug of hot water will be expelled
It is advisable that the showering temperature
is satisfactory by testing with your hand
before stepping under the showerhead.
There will always be a time delay of a few
the water reaching the stable temperature for
- During spring and autumn time, suggest to
use I (ECO) or II power;
- During summer time, suggest to use Cold
or I (ECO) power;
- During winter time, suggest to use III power.
Setting change delay
Avoid scalding water
Power setting suggestion
The temperature indicator will show a error code
when the shower is in malfunction. Below table
show what the error code mean.
This product cannot afford very high external
water pressure for safety use and usage life
reasons, highest limitation is 6-9 bar, and
PRD as product's pressure relief device,
when external factors like handset block
happens and causes heater can not stand
the internal pressure reaches the highest limit,
PRD will break up to release water pressure,
point to release pressure and provide
protection.
Error code
PRD – Pressure Relief Device
thermal cut-out safety device. In the event of
abnormal operation which could cause
unsafe temperatures (≥ 80°) within the unit,
the device will disconnect the heating
determine the cause of the fault and handle
the repair work.
Low water pressure protection
Low water pressure protection
If inlet water pressure is too low, less than
0.6-0.9 bar, then microswitch cannot be
connected, so heating will not start, it can
temperature or heating without water.
The shower has pressure relief device, when
outlet water pressure is higher than 6-9 bar
burst pressure, rubber seal inside pressure
out from there to release pressure and
protect product. After pressure is released,
pressure relief valve cannot be reset, until
rubber seal need to be replaced manually.
0.05mm3 impurity entering into product,
avoid block of internal water pipe and lime
scale.
Error
code No.
Error code
Reason
E1
LP
Temperature sensor failure
Low water pressure
22 www.electrolux.com