TROUBLESHOOTING
Problem/Symptom
Cause
Action/Cure
Shower fail to
operable, no water
flow out.
Interrupted power supply.
Unit malfunction.
Blown fuse or circuit breaker. Check
supply. Renew or reset fuse or circuit
breaker. If it fails again, consult a qualified
electrician.
Check other appliances and if necessary,
contact local Electricity Supply Co. Have
unit checked. If the it still fail to operate,
contact Electrolux Customer Service.
Increase flow rate via temperature control.
Water too hot.
Water temperature
cycling hot/cool at
intervals.
Water too cool
or cold.
Not enough water flowing
through the shower.
Blockage in supply.
Increase in ambient
water temperature.
Heater cycling on
temperature limiter.
Too much flow.
Water pressure below
minimum required
(see rating label).
Reduction in ambient
water temperature.
Electrical malfunction.
Safety cut-out operated.
Blocked showerhead — clean or replace
blocked sprayplate in showerhead.
Check if stop valves are fully open. Check
if a blockage in the inlet filter.
See 'Water too hot' causes and their
appropriate action/cures. If it continues
contact Electrolux Customer Service.
Reduce flow rate via temperature control.
Readjust flow rate to give reduced flow or
select higher power.
Have unit checked by suitably qualified
electrician or contact Electrolux Customer
Service.
Thermal safety cut-out device has
operated. Have the unit checked by a
suitably qualified engineer or contact
Electrolux Customer Service.
Is it water supply mains or tank fed?
If tank fed, replumb to mains water supply.
If mains fed, make sure that mains
stopvalve is fully open and that there are
no other restrictions in the supply while
shower is in use.
Fit pump to give minimum pressure (see
rating label). Electrolux Contact Customer
Service for advice.
Readjust flow rate to give increased flow
or sele
ct ‘ECO’ pow
er.
Switch OFF the electricity at the mains supply and remove the circuit fuse before attempting
any fault finding inside the unit.
WARNING!
23
ENGLISH