background image

6.

When a smooth flow of water is obtained, 

rotate the temperature control from MINIMUM 
to MAXIMUM several times to release any 
trapped air within the unit.

7.

Once flushing out has been completed, 

stop the water flow by pressing the On/off 
button.

8.

Fit the showerhead to the flexible hose and 

place in the showerhead holder.

The shower is now ready for normal operation.

Make sure the commissioning procedure 
has been carried out.

Press the On/off button and water will flow.

Press the On/off button again and water 
will cease to flow.

When not using the shower unit, insolate 
the unit from main circuit via the double 
pole switch.

Cold:

 the cold setting does not provide 

any heat from the heater to the incoming 
water.

I(ECO):

 Uses only the low power heating 

element within the shower unit.

II:

 Uses the high power heating element 

within the shower unit.

III:

 Uses both of the low/high heating 

elements within the shower unit to provide 
the highest heating efficiency.

NOTE: It will take a few seconds for the 
temperature to stabilise after changing the 
Heating power knob position.

The water temperature is altered by 
increasing or decreasing the flow rate of 
the water through the shower via the 
temperature control.

After obtaining your showering temperature, 
the knob can be left as the normal setting 
and should only need altering to 
compensate for seasonal changes in 
ambient water temperature.

Turn the temperature control anti-clockwise 
- this will increase the flow of water through 
the shower and make the water colder.

NOTE:

 The preferred knob position on 

ECONOMY will give a different temperature 
to the same position on HIGH.

To decrease the shower temperature

To adjust the shower temperature 
(ECO and “II” or “III” settings only)

The power selector has four positions - 
Cold “     ”, I(ECO) “     ”, II “     ” and 
III “     ”.

To start the shower

To stop the shower

To use the power selector

6.3

Daily use

If restarting immediately after stopping,
be aware that a slug of hot water will 
be expelled for the first few seconds.

WARNING!

Fig. 16

Temperature control -
Turn fully anti-clockwise
to MAXIMUM flow

19

ENGLISH

3.

Turn on the mains water supply to the 

shower at the isolating stopvalve and then 
turn on the electric supply to the shower at 
the isolating switch.

4.

Press the On/off button

 an

d wait until 

water starts to flow from the flexible hose.

5.

Slowly rotate the temperature control fully 

anti-

clockwise to the MAXIMUM flow position 

(Fig.16).

It will take about thirty seconds for a 

smooth flow of water to be obtained while air 
and any debris is flushed from the shower.

Failure to turn the control to the 
minimum flow position MAY cause 
the PRD(Pressure Relief Device) to 
operate.

CAUTION!

6.

OPERATION INSTRUCTION

Summary of Contents for EYL10516WM

Page 1: ...EYL85016WM EYL95016WM EYL10516WM WATER HEATER USER MANUAL ...

Page 2: ...s every time Welcome to Electrolux Visit our website to Get usage advice brochures trouble shooter service information www electrolux com Register your product for better service www electrolux com productregistration Buy Accessories Consumables and Original spare parts for your appliance www electrolux com shop 2 SAFETY INSTRUCTIONS 6 3 ELECTRICAL REQUIREMENTS 8 1 SAFETY INFORMATION 4 4 WATER REQ...

Page 3: ...ase visit www electrolux co uk Please ensure you read the information under What to do if in your instruction booklet before contacting us for service Servicing and or installation of your product including electrical connections and water connections should be carried out by a suitably qualified engineer In the user manual and on our web site www electrolux co uk you will find some useful informa...

Page 4: ...and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved 1 SAFETY INFORMATION 1 1 Children and vulnerable people safety 1 2 General Safety Keep all packaging away from children Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Before mai...

Page 5: ... the fixed wiring in accordance with the wiring rules The fixed wiring insulation must be protected for example by insulating sleeving having an appropriate temperature rating The pressure relief device must be fitted during installation unless it is incorporated in the appliance The appliance must be permanently connected to fixed wiring 5 ENGLISH ...

Page 6: ...r earth leakage trips and contactors Always switch off the power at the consumer unit and isolate the electrical supply before making any electrical connections or if you have to remove the cover of an installed unit Remove all the packaging labeling and protective film if applicable before first use Obey the installation instruction supplied with the appliance Keep the minimum distance from the o...

Page 7: ... or if the water is leaking from the shower unit itself Turn off at the mains electrical supply and refer to the Troubleshooting section see page 23 or contact Electrolux Customer Services see page 3 Do not crush or kink the shower hose this could damage the hose cause leaks and activate the pressure relief device Contact your municipal authority for information on how to discard the appliance cor...

Page 8: ...ng above 9kW it is advisable to contact the local electricity supply company The shower must be connected to its own independent electrical supply It must not be connected to a ring main spur power socket or lighting circuit The electrical supply must be adequate for the loading of the unit and existing circuits Check your consumer unit main fuse box has a main switch rating of 80A or above and th...

Page 9: ...wice the diameter of the cable or conduit Unit Rating 240V Circuit Protection Device MCB Cartridge Fuse 8 5kW 9 5kW 10 5kW 40A 45A 40 45A 45A 45A 45A Cable current carrying capacity table for twin and earth PVC insulated cable Current carrying capacity In an insulated wall In conduit or trunking Clipped direct or buried in a non insulated wall 6mm 32A 6mm 38A 6mm 46A 10mm 43A 10mm 52A 10mm 63A Not...

Page 10: ...vent back flow It is required that the showerhead be constrained by a fixed or sliding attachment so that it can only discharge water at a point not less than 25mm above the spill over level of the relevant bath shower tray or other fixed appliance If the shower is to be installed in a hard water area we recommend that an in line scale inhibitor is fitted which will prolong the life of the shower ...

Page 11: ...cess cover screws Position the unit where it will NOT be in direct contact with water from the showerhead Position the shower unit vertically The shower should be 1m minimum height from floor Take the proper water and cable entry position into consider while selecting the installation position See Fig 1 for the water and cable entry position options Fig 1 Before installation make sure you read thr...

Page 12: ...t from the wall Using the installation template supplied mark the positions of the three fixing holes To mark the drilling position Check if there is any buried pipes or cables before drilling CAUTION NOTE Ensure that there are sufficient lengths of supply pipe and electrical cable to reach the connection points as shown on the template Remove the installation template and drill the fixing holes d...

Page 13: ...erminal block you need to pull out the steel fastening strip first and fix it on the terminal block again when you put the terminal block on the right side After that try to pull the terminal block out to check if it is fixed Fig 4a Fig 4b Terminal block Fig 4 5 2 Plumbing connection To remove the front cover Hook the backplate over the top screw and fit the bottom fixing screws into position but ...

Page 14: ...is and swarf that could otherwise damage the unit 21mm Fig 5 14 www electrolux com Wiring terminal Earthing terminal 2 Adjust the spline spindle and the control knob to the correct position before replacing the cover Fig 7 8 show the correct pline spindle and the control knob position 1 Before fixing the front cover to the shower tighten the 3 screws to fix the shower on the wall firmly 5 4 Fixing...

Page 15: ...ce is felt 2 Flat section to left hand side Stabiliser valve 3 Reassemble the water inlet cover 4 Check to ensure that the wiring is not trapped and replace the cover squarely to the backplate and guide into position so that the knobs locate correctly into the splined spindles Should any difficulty arise recheck the points above 5 While applying slight pressure to the cover secure in position with...

Page 16: ...1 NOTE Use the flexible hose to locate the proper position for the bracket if necessary Put the wall plugs on the holes then remove the sliding rail holder covers from the sliding rail holders and fix one of the sliding rail holders on the upper position then replace the sliding rail holder cover 3 Check if there is any buried pipes or cables before drilling WARNING NOTE When fixing the sliding ra...

Page 17: ...sliding rail between the holders and fix the sliding rail by fixing the lower holder as Fig 13 shown b Assemble the soap tray holder from the bottom of the sliding rail as Fig 12 shown Point the open gap upward The larger hole should be pointed outside Fig 13 Fig 12 17 ENGLISH ...

Page 18: ...mmissioning procedure is completed correctly The following operation is intended to flush out any remaining debris and to make sure the heater unit contains water before the heating elements are switched on 1 Make sure the flexible hose is screwed to the water outlet but WITHOUT THE SHOWERHEAD ATTACHED and the outlet of the flexible hose is directed to waste 2 Before turning on the electric and ma...

Page 19: ...g temperature the knob can be left as the normal setting and should only need altering to compensate for seasonal changes in ambient water temperature Turn the temperature control anti clockwise this will increase the flow of water through the shower and make the water colder NOTE The preferred knob position on ECONOMY will give a different temperature to the same position on HIGH To decrease the ...

Page 20: ...CTION Turn the temperature control clockwise this will decrease the flow of water through the shower and make the water hotter NOTE t Total rotation distance of the temperature knob is 300 t It is advisable that the showering temperature is satisfactory by testing with your hand before stepping under the showerhead There will always be a time delay of a few seconds between selecting a flow rate an...

Page 21: ...er see page 16 for information on commissioning procedure Fig 17 You can use a clean cloth to wipe the front panel O ring Filter assembly Do not use brushes emery paper or burnishes to clean the unit because it may cause damages While cleaning the front panel Do not use a chemically treated cloth or duster to clean the unit Do not use benzine thinner polishing powder or similar solvents for cleani...

Page 22: ...t PRD will break up to release water pressure and water flows out from the breaking up point to release pressure and provide protection During spring and autumn time suggest to use I ECO or II power During summer time suggest to use Cold or I ECO power During winter time suggest to use III power Setting change delay Avoid scalding water Test the temperature first Power setting suggestion PRD Press...

Page 23: ...replace blocked sprayplate in showerhead Check if stop valves are fully open Check if a blockage in the inlet filter See Water too hot causes and their appropriate action cures If it continues contact Electrolux Customer Service Reduce flow rate via temperature control Readjust flow rate to give reduced flow or select higher power Have unit checked by suitably qualified electrician or contact Elec...

Page 24: ... while commissioning Faulty start stop switch Debris in the solenoid Check for free passage through hose Replace the hose if necessary and fit new PRD Fit new PRD Commission unit with showerhead removed Replace start stop switch Replace solenoid valve NOTE Identify the cause of operation before fitting a new PRD unit When fitting a new PRD follow the commissioning procedure t It is advised all ele...

Page 25: ...5519W17170 000 001 www electrolux com shop ...

Reviews: