6.
When a smooth flow of water is obtained,
rotate the temperature control from MINIMUM
to MAXIMUM several times to release any
trapped air within the unit.
7.
Once flushing out has been completed,
stop the water flow by pressing the On/off
button.
8.
Fit the showerhead to the flexible hose and
place in the showerhead holder.
The shower is now ready for normal operation.
Make sure the commissioning procedure
has been carried out.
Press the On/off button and water will flow.
Press the On/off button again and water
will cease to flow.
When not using the shower unit, insolate
the unit from main circuit via the double
pole switch.
Cold:
the cold setting does not provide
any heat from the heater to the incoming
water.
I(ECO):
Uses only the low power heating
element within the shower unit.
II:
Uses the high power heating element
within the shower unit.
III:
Uses both of the low/high heating
elements within the shower unit to provide
the highest heating efficiency.
NOTE: It will take a few seconds for the
temperature to stabilise after changing the
Heating power knob position.
The water temperature is altered by
increasing or decreasing the flow rate of
the water through the shower via the
temperature control.
After obtaining your showering temperature,
the knob can be left as the normal setting
and should only need altering to
compensate for seasonal changes in
ambient water temperature.
Turn the temperature control anti-clockwise
- this will increase the flow of water through
the shower and make the water colder.
NOTE:
The preferred knob position on
ECONOMY will give a different temperature
to the same position on HIGH.
To decrease the shower temperature
To adjust the shower temperature
(ECO and “II” or “III” settings only)
The power selector has four positions -
Cold “ ”, I(ECO) “ ”, II “ ” and
III “ ”.
To start the shower
To stop the shower
To use the power selector
6.3
Daily use
If restarting immediately after stopping,
be aware that a slug of hot water will
be expelled for the first few seconds.
WARNING!
Fig. 16
Temperature control -
Turn fully anti-clockwise
to MAXIMUM flow
19
ENGLISH
3.
Turn on the mains water supply to the
shower at the isolating stopvalve and then
turn on the electric supply to the shower at
the isolating switch.
4.
Press the On/off button
an
d wait until
water starts to flow from the flexible hose.
5.
Slowly rotate the temperature control fully
anti-
clockwise to the MAXIMUM flow position
(Fig.16).
It will take about thirty seconds for a
smooth flow of water to be obtained while air
and any debris is flushed from the shower.
Failure to turn the control to the
minimum flow position MAY cause
the PRD(Pressure Relief Device) to
operate.
CAUTION!
6.
OPERATION INSTRUCTION