SOI/DT 2002-07 eb
45
599 35 36-69
Alarm
Description
Possible fault
Action/machine status
Reset
E61
Insufficient heating during washing
NTC sensor faulty; heating element faulty; wiring faulty; PCB
faulty.
The heating phase is skipped
---
E62
Overheating during washing
NTC sensor faulty; heating element faulty; wiring faulty; PCB
faulty.
Safety drain cycle – Cycle stopped
with door open
OFF
E66
Heating element power relay faulty
PCB faulty; current leakage from heating element to ground.
Safety drain cycle – Cycle stopped
with door open
OFF
E71
Washing NTC sensor faulty
NTC sensor faulty; wiring faulty; PCB faulty.
The heating phase is skipped
Start
E82
Error in selector reset position
PCB faulty.
---
OFF
E83
Error in reading selector
(Incorrect configuration data); PCB faulty.
Cycle cancelled
---
E93
Incorrect configuration of appliance
Incorrect configuration data; PCB faulty.
Cycle interrupted
OFF
E94
Incorrect configuration of washing cycle
Incorrect configuration data; PCB faulty.
Cycle interrupted
OFF
E95
Communications error between
microprocessor and EEPROM
PCB faulty.
Cycle interrupted
OFF
E96
Incongruency between hardware version
and configuration
Incorrect configuration data; PCB faulty.
Cycle interrupted
OFF
E97
Incongruency between programme selector
and cycles configuration
Incorrect configuration data; PCB faulty.
Cycle interrupted
OFF
EB1
Incorrect frequency of appliance
Power supply problems (incorrect / disturbance); PCB faulty.
Cycle interrupted
---
EB2
Voltage too high
Power supply problems (incorrect / disturbance); PCB faulty.
Cycle interrupted
---
EB3
Voltage too low
Power supply problems (incorrect / disturbance); PCB faulty.
Cycle interrupted
---