SOI/DT 2002-07 eb
41
599 35 36-69
8 ALARMS
8.1 Displaying the alarms to the user
Control of the alarm system can be configured; according to the model, therefore, some or all of the
alarms may be displayed to the user.
Normally, all alarms are displayed to the user, with the exception of:
-
E61 (insufficient heating during the washing phase),
-
E83 (error in selector reading)
The alarms are enabled during the execution of the washing programme, with the exception of alarms
associated with configuration and the power supply (voltage/frequency), which are also displayed during the
programme selection phase.
The door can normally be opened (except where specified) when an alarm condition has occurred on
condition that:
•
The level of the water in the tub is below 1st level
•
The temperature of the water is lower than 40°C.
Certain alarm conditions require a drain phase before the door can be opened:
•
Cooling water fill if the temperature is in excess of 60°C.
•
Drain until closure of both pressure switch contacts (1st level and anti-boiling safety system) on EMPTY
within a maximum of 5 minutes.
8.1.1 Displaying the alarms during normal operation
The type of alarm condition is displayed to the user by the repeated flashing of the
END OF CYCLE LED (0.4 seconds lit, 0.4 seconds off, with an interval of 2.5
seconds between sequences). This LED is featured on all models, though
configured in different positions.
END OF CYCLE LED
ON / OFF
Time
(sec.)
Value
0.4 1
0.4
0.4 2
0.4
0.4 3
0.4
0.4
4
0.4
If, for example, the user should forget to close the door, the
control system will detect alarm E41 about 15 seconds after
the start of the cycle; the cycle remains in PAUSE mode and
the LED flashes repeatedly in the sequence shown in the
table.
The four flashes indicate the first of the two digits of alarm E
4
1
(the alarms for a given function are grouped in “families”).
In this case, after closing the door, it is sufficient to press
START in order to re-start the programme.
2.5
Pause
between
sequences
Configuration errors
E93-E96
are displayed by the lighting of all the LEDs.