6.5 Control pressure switch for water level in the tub
Control of the water level is performed by a three-level pressure switch which functions as follows:
•
contact
11-14
: anti-boiling safety level
•
contact
21-24
: first level
•
contact
31-32
: anti-overflow safety level
(some models may not feature it)
6.5.1 Pressure switch settings
Full (mm)
Refill (mm)
Anti-boiling level
55
±
3
35
±
3
1st level
75
±
3
55
±
3
Anti-overflow
level
390
±
15
240
±
50
6.5.2 Water fill without wash load
The table below shows the average water fill to reach the anti-boiling level and the first level without wash
load: data are gathered with empty drain circuit (if the drain circuit has not been emptied the water quantity
is reduced by about 0,7 litres).
G19 tub
Anti-boiling level (litres)
3,5 (3,4
÷
3,7)
1st level (litres)
5,6 (5,4
÷
6)