Important Notes to the Installer

1.  Read all instructions contained in these installation 

instructions before installing the combination oven.

2.  Remove all packing material from the oven 

compartments before connecting the electrical supply 
to the wall oven.

3.  Observe all governing codes and ordinances.
4.  Be sure to leave these instructions with the consumer.
5.  Oven door may be removed to facilitate installation.
6. 

THIS COMBINATION OVEN IS NOT APPROVED FOR 
STACKABLE OR SIDE-BY-SIDE INSTALLATION.

Important Note to the Consumer

Keep these instructions with your Owner's Guide for 
future reference. Do not discard oven removal tools found 
in the literature bag.

IMPORTANT SAFETY 
INSTRUCTIONS

 Be sure your combination oven is installed and 

grounded properly by a qualified installer or 
service technician.

• 

This wall oven must be electrically grounded in 
accordance with local codes or, in their absence, 
with the National Electrical Code ANSI/NFPA 
No.70- latest edition in United Sates, or with CSA 
Standard C22.1, Canadian Electrical Code, Part 1, 
in Canada.

 Stepping, leaning or sitting on the 

door of this wall oven can result in serious injuries 
and can also cause damage to the wall oven.

• 

Never use your wall oven for warming or heating 
the room. 

Prolonged use of the wall oven without 

adequate ventilation can be dangerous.

 The electrical power to the oven must 

be shut off while line connections are being made. 
Failure to do so could result in serious injury or 
death.

1. Carpentry

Refer to figure 1 for the dimensions applicable to 
your appliance, and the space necessary to receive the 
combination oven. The oven support surface may be 
solid plywood or similar material, however the surface 
must be leveled from side to side and from front to rear.

2. Electrical Requirements

This appliance must be supplied with the proper voltage 
and frequency, and connected to an individual, properly 
grounded branch circuit, protected by a circuit breaker 
or fuse. To know the circuit breaker or fuse required 
by your model, see the serial plate to find the wattage 
consumption and refer to table A to get the circuit 
breaker or fuse amperage.

Table A

Appliance 

Rating Watts

240V

Protection 

Circuit 

Recommended

Appliance 

Rating Watts

208V

Protection 

Circuit 

Recommended

Less than 4800W

20A

Less than 4100W

20A

4800W - 7200W

30A

4100W - 6200W

30A

7200W - 9600W

40A

6200W - 8300W

40A

9600W and +

50A

8300W and +

50A

Observe all governing codes and local ordinances

1. A 3-wire or 4-wire single phase 120/240 or 120/208 

Volt, 60 Hz AC only electrical supply is required on a 
separate circuit fused on both sides of the line (red 
and black wires). A time-delay fuse or circuit breaker is 
recommended. DO NOT fuse neutral (white wire).

NOTE:

 Wire sizes and connections must conform with 

the fuse size and rating of the appliance in accordance 
with the American National Electrical Code ANSI/NFPA 
No. 70-latest edition, or with Canadian CSA Standard 
C22.1, Canadian Electrical Code, Part 1, and local codes 
and ordinances.

 An extension cord should not be used 

with this appliance. Such use may result in a fire, 
electrical shock, or other personal injury. 

If you need 

a longer power cord you can purchase a 10' (3 m) power 
cord kit by calling the Service Center

.

2.  These appliances should be connected to the fused 

disconnect (or circuit breaker) box through flexible 
armored or nonmetallic sheathed cable. The flexible 
armored cable extending from the appliance should 
be connected directly to the junction box. The 
junction box should be located as shown in Figure 1 
and with as much slack as possible remaining in the 
cable between the box and the appliance, so it can 
be moved if servicing is ever necessary.

3.  A suitable strain relief must be provided to attach 

the flexible armored cable to the junction box.

 In cold weather shipping and storage 

conditions, make sure that oven is in final location 
at least three (3) hours before switching on power. 
Switching on power while oven is still cold may damage 
the oven controls.

Summary of Contents for EW27MC65JB

Page 1: ...d dimension 4 For a cutout height H between 44 111 8cm and 445 8 113 3 cm add a 2 5 cm wide wood shim of appropriate height to each side of the opening under the appliance side rails Lifting the unit will allow you to hide the cutout openings showing above the unit The bottom trim of the unit will hide the shims at the bottom 5 For a cutout height H between 445 8 113 3 cm and 463 8 117 8 cm you ca...

Page 2: ...d to an individual properly grounded branch circuit protected by a circuit breaker or fuse To know the circuit breaker or fuse required by your model see the serial plate to find the wattage consumption and refer to table A to get the circuit breaker or fuse amperage Table A Appliance Rating Watts 240V Protection Circuit Recommended Appliance Rating Watts 208V Protection Circuit Recommended Less t...

Page 3: ...y connection of grounding lead to neutral lead at the termination of the conduit if used in USA in a new branch circuit installation 1996 NEC mobile home recreational vehicles where local code do not permit grounding trough the neutral white wire or in Canada disconnect the white and green lead from each other and use ground lead to ground unit in accordance with local codes connect neutral lead t...

Page 4: ...ove the bottom trim taped on the oven side panel 2 Remove the lower oven door to reduce the weight of the appliance and to facilitate its handling and its installation Heavy Weight Hazard Use 2 or more people to move and install wall oven Failure to follow this instruction can result in injury or damage to the unit IMPORTANT NOTE Do not lift the oven by the door handle To remove the oven door see ...

Page 5: ... the hole for it in the cabinet and toward the junction box while moving the appliance inward 7 Install now the bottom trim using the screws supplied with the unit Figure 8 5 Insert the unit into the cabinet opening Slide unit inward leaving 1 3 8 cm clearance between the unit and front of cabinet see Figure 7 Figure 7 1 3 8 cm clearance between unit 8 Install now the center trim using the screws ...

Page 6: ...e oven is set for a convection baking or roasting both elements cycle on and off alternately and the convection fan will run The convection fan will stop running when the oven door is opened Before You Call for Service Read the Before You Call for Service Checklist and the Operating Instructions in your Use and Care Guide It may save you time and expense The list includes common occurrences that a...

Page 7: ...007 Rev D Toutes les dimensions sont en pouces cm Figure 1 NOTES 1 La base doit pouvoir supporter 275 lbs 125 kg pour les modèles 27 et 350 lbs 159 kg pour les modèles 30 2 Allouez au moins 21 53 3 cm d espace à l avant du four pour permettre l ouverture complète de la porte du four 3 La dimension G profondeur du découpage est critique pour une bonne installation du four Si la moulure inférieure d...

Page 8: ...ion possédant la tension et la fréquence appropriées Il doit être connecté à un circuit dédié correctement mis à la terre et protégé par un disjoncteur ou un fusible Pour savoir quel disjoncteur ou fusible utiliser avec cet appareil référez vous à la plaque signalétique pour connaître la consommation watts et avec cette donnée consultez la table A pour connaître l ampérage requis du disjoncteur ou...

Page 9: ...e à la terre du châssis au neutre ou au Canada débranchez les fils blanc et vert des autres et utilisez le fil de mise à la terre pour mettre à la terre l appareil conformément aux codes locaux branchez le conducteur neutre de manière habituelle au circuit neutre voir la figure 3 Si l appareil doit être branché à un câble à 3 fils aux États Unis seulement où les codes locaux permettent la connexio...

Page 10: ... déplacer l appareil Des blessures ou des dommages à l appareil peuvent survenir si vous ne suivez pas cette instruction NOTE IMPORTANTE Ne soulevez pas l appareil par la poignée de la porte Figure 3 BOÎTE DE JONCTION À 4 FILS MISE À LA TERRE Câble d alimentation Fil blanc Boîte de jonction Câble de l appareil Fil dénudé ou vert Fil dénudé Fil blanc Fils noirs Fils rouges Connecteur homologué U L ...

Page 11: ...z le câble gainé à travers le trou du plancher de l armoire et vers la boîte de jonction 7 Installez maintenant la moulure décorative inférieure avec les vis fournies avec l appareil Figure 8 5 Insérez l appareil dans le découpage de l armoire Glissez l unité vers l intérieur en laissant un espace de 1 3 8 cm entre le four et le devant de l armoire voir figure 7 Figure 7 8 Installez maintenant la ...

Page 12: ...fications préventives et les instructions d opération dans votre Manuel d utilisation et d entretien Vous sauverez probablement du temps et de l argent La liste contient les incidents ordinaires ne résultant pas de défectuosités dans le matériel ou la fabrication de cet appareil Pour obtenir notre adresse et notre numéro de téléphone sans frais référez vous à votre Manuel d utilisation et d entret...

Reviews: