- 9 -
TSE-N 12.99 A. B.
599 50 72 16
EN
Programme 3 - see basic setting 1 - 5
Programme number
3
white
33
Oven sensor
red
Food thermometer
white
30
2
white
Programme 3 shows the temperature of the oven sensor and the food thermometer (if
inserted).
Note!
The two temperatures normally differ because different measuring points
are used.
Programme 4 - see basic setting 1 - 5
If the power supply is disconnected after detecting the fault, the information is deleted
and fault code 000 appears on executing test programme 4.
If a fault has been detected but the cause of the fault no longer exists (temporary fault)
because the temperature has dropped or the cooking thermometer has been
disconnected from the socket, the relevant fault code is stored in the memory and can
be read out via test programme 4 as long as the power supply is not disconnected.
Programme number
4
white
000
Fault code
red