- 10 -
TSE-N 12.99 A. B.
599 50 72 16
EN
Fault reports for programme 4
Functional description:
When this module is activated, it handles all the faults present and carries out an
EEPROM check. As soon as a fault occurs, a fault register has access to the main
processor control loop. This causes the control to switch from the current status to the
fault mode (except when in the test mode): If a new fault occurs which has a higher
priority than the preceding fault, only this higher fault code is displayed. The last fault
occurring with the highest priority is stored and can be displayed by Service Test Mode
4 at any time. The fault with the highest priority is the EEPROM control fault »F«.
Fault code
Type of fault
000
No fault
001
Food thermometer open-circuit
∝ Ω
002
Fodd thermometer short-circuit
Ω
003
Appers when an attempt is made to switch on
the appliance again in spite of fault code display
002 odr 003.
Fault in safety circuit.
004
Appers when the child safety system is to be
switched on but the circuit is faulty
005
Not used
006
The temperature measured by the oven sensor
exceeds the temperature set by the
programming unit
007
Other tests of the oven probe and display board
probe, excluding disconnection and short-circuit
(test fault)
008
Thermostat on the board has operated
009
Thermostat on the board is short-circuit
00 A
Thermostat on the board is open-circuit
00 B
Not used
00 C
Not used
00 D
Oven sensor is short-circuit
00 E
Oven sensor is disconnected
00 F
EEPROM fault (microprocessor)