Page 1: ...user manual Freezer EUF29420W EUF29420X EUF29420K EUF29425W EUF29425X EUF29430W EUF29430X ...

Page 2: ...nce Keep all packaging well away from chil dren There is risk of suffocation If you are discarding the appliance pull the plug out of the socket cut the con nection cable as close to the appliance as you can and remove the door to pre vent playing children to suffer electric shock or to close themselves into it If this appliance featuring magnetic door seals is to replace an older appliance having...

Page 3: ...od in accord ance with the frozen food manufacturer s instructions Appliance s manufacturers storage rec ommendations should be strictly adhered to Refer to relevant instructions Do not place carbonated or fizzy drinks in the freezer compartment as it creates pressure on the container which may cause it to explode resulting in damage to the appliance Ice lollies can cause frost burns if con sumed ...

Page 4: ...iance shall not be discarded together with the urban refuse and rubbish The insulation foam contains flammable gases the appli ance shall be disposed according to the applicable regulations to obtain from your local authorities Avoid dam aging the cooling unit especially at the rear near the heat exchanger The ma terials used on this appliance marked by the symbol are recyclable CONTROL PANEL B D ...

Page 5: ...ated It is possible to de activate the function at any time by pressing key D until the corre sponding icon will flash and then key E Eco Mode Function The Eco Mode function is activated by pressing button D several times if necessa ry until the corresponding icon appears or setting the temperature at 18 C You must confirm the choice by pressing button E within few seconds You will hear the buzzer...

Page 6: ...again the set temperature During the alarm phase the buzzer can be switched off by pressing button E Door open alarm An acoustic alarm will sound if the door is left open for a few minutes The door open alarm conditions are indicated by flashing icon acoustic buzzer When normal conditions are restored door closed the alarm will stop During the alarm phase the buzzer can be switched off by pressing...

Page 7: ... a power failure if the power has been off for longer that the value shown in the technical characteristics chart under rising time the defrosted food must be consumed quickly or cooked immediately and then re frozen after cooling Thawing Deep frozen or frozen food prior to being used can be thawed in the refrigerator compartment or at room temperature de pending on the time available for this ope...

Page 8: ...it open longer than absolutely necessary Once defrosted food deteriorates rapidly and cannot be refrozen Do not exceed the storage period indica ted by the food manufacturer CARE AND CLEANING Caution Unplug the appliance before carrying out any maintenance operation This appliance contains hydrocarbons in its cooling unit maintenance and re charging must therefore only be carried out by authorized...

Page 9: ...iance some smaller but annoying trouble can often oc cur which does not require calling a techni cian out In the following chart information is given about them to avoid unnecessary charges on service Important The operation of the appliance goes with certain sounds compressor and circulating sound This not means a trouble but a normal operation Important The appliance operates discontinuously so ...

Page 10: ...e is cold air circulation Large quantities of food to be frozen were put in at the same time Insert smaller quantities of food to be frozen at the same time The appliance does not operate The appliance is switched off Switch on the appliance The mains plug is not connected to the mains socket correctly Connect the mains plug to the mains socket correctly The appliance has no power There is no volt...

Page 11: ...3 C Location To ensure best performance if the appli ance is positioned below an overhanging wall unit the minimum distance between the top of the cabinet and the wall unit must be at least 40 mm Ideally however the appliance should not be positioned be low overhanging wall units The ventilation space can be directly above the appliance behind and above the top cupboard In this case the space behi...

Page 12: ...he panel Levelling When placing the appliance ensure that it stands level If necessary adjust the feet us ing the adjustment spanner supplied Door reversibility To change the opening direction of the door do these steps 1 Remove the plug from the power 2 Remove the ventilation grille Remove the upper filling and install it on the op posite side of the grille Remove the pedal hole cover and in stal...

Page 13: ...c seal adheres to the cabi net The door opens and closes correctly If the ambient temperature is cold i e in Winter the gasket may not fit perfectly to the cabinet In that case wait for the natural fitting of the gasket ENVIRONMENTAL CONCERNS The symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead it should be taken to the appropriate...

Page 14: ...14 electrolux ...

Page 15: ...electrolux 15 ...