Do a final check to make
sure that:
• All screws are tightened.
• The magnetic seal
adheres to the cabinet.
• The door opens and
closes correctly.
If the ambient temperature is
cold (i.e. in Winter), the
gasket may not fit perfectly
to the cabinet. In that case,
wait for the natural fitting of
the gasket.
In case you do not want to
carry out the above
mentioned operations,
contact the nearest
Authorised Service Centre.
The Authorised Service
specialist will carry out the
reversibility of the doors at
your cost.
3.6 Electrical connection
• Before plugging in, ensure that the
voltage and frequency shown on the
rating plate correspond to your
domestic power supply.
• The appliance must be earthed. The
power supply cable plug is provided
with a contact for this purpose. If the
domestic power supply socket is not
earthed, connect the appliance to a
separate earth in compliance with
current regulations, consulting a
qualified electrician.
• The manufacturer declines all
responsibility if the above safety
precautions are not observed.
• This appliance complies with the
E.E.C. Directives.
4. OPERATION
4.1 Control panel
1
2
3
4
5
1
Green On/Off Power Indicator Light
2
Temperature Regulator and On/Off
Switch
3
Yellow FastFreeze Indicator Light
4
Acoustic Signal Stop and FastFreeze
Switch
5
Red Alarm Indicator Light
4.2 Switching on
Leave the appliance to stand upright for
4 hours after installation.
1. Insert the plug into the wall socket.
2. Turn the Temperature Regulator
clockwise to a medium position.
The Green On/Off Indicator Light will
light up and Red Alarm Indicator
Light will blink.
The lighting up of the Green On/Off
Indicator Light means that the
appliance is switched on.
www.electrolux.com
8