8 www.electrolux.com
3.1
Indoor unit installation
3.1.1
Installing the Wall Mounting
Plate
1.
Install the wall mounting plate
horizontally over the structural parts on
the wall using the spaces indicated on
the plate, as shown in Fig.3.1.1.
2.
In the case of tiled, concrete or
similar walls, create 5mm diameter
holes. Place anchor supports for the
appropriate assembly screws.
3.
Install the wall mounting plate to the
wall with screws.
Fig.3.1.1
NOTE:
• Fit the wall mounting plate and drill
holes in the wall according to the wall
structure and corresponding mounting
points on the wall mounting plate.
• Refer to
Appendix(1)
for type details
about the mounting plates.
3.1.2
Drilling the Hole
1.
Determine the position of the hole for
the pipes using the wall mounting plate
and drill the pipe hole so that it is tilted
slightly downward.
2.
Always use a pipe cover with an
opening when drilling.
Fig.3.1.2
5-7mm
Wall
Indoor
Outdoor
3.1.3
Connective pipe
1.
For the left-hand and right-hand piping,
remove the pipe cover from the side
panel. The pipe cover can be kept as
it may be used when relocating the air
conditioner to any other place.
2.
For the rear-right-hand and rear-left-
hand piping, install the piping as shown
in Fig.3.1.3-1. Bend the connective
pipe to be laid at a height of 43mm or
less from the wall. Fix the end of the
connective pipe.
Fig.3.1.3-1
Fig.3.1.3-2
3.1.4
Drainage
1.
Run the drain hose sloping downward.
Do not install the drain hose as
illustrated in Fig.3.1.4.
Fig.3.1.4
Do not block water flow by a rise or
put the end of drain hose into water.
Indoor Unit
Outline
Connective Pipe
43mm
Pipe Cover
(right)
Right
Piping
Rear Right
Piping
Rear Left
Piping
Pipe Cover
(left)
Pipe Holder
3.
PRODUCT INSTALLATION