Notes for Test Institutes
Testing in accordance with EN 60704
must be car-
ried out with the appliance fully loaded and using the
test cycle (see “Cycle Table”).
Tests in accordance with EN 50242
must be car-
ried out when the salt dispenser in the water softener
and the rinse aid dispenser have been filled with salt
and rinse aid respectively, and using the test cycle
(see “Cycle Table”).
Sample loading arrangements:
Full load:
12 place settings
including serving dishes
Half load:
6 place settings including serving dishes,
leaving alternate positions in the rack free
Amount of detergent re-
quired:
5g + 25g (Type B)
20g (Type B)
Rinse aid setting:
4 (Type III)
4 (Type III)
Upper basket
*)
*) If necessary, move the cup rack from right to left. When doing this, ensure that the cup rack is at the same height.
Lower basket with cutlery basket
*)
Cutlery basket
*) If there are cup racks in place on the lefthand side or if beer glass holders are in place, remove them.